Lenovo IBM System x3650 M5

Lenovo IBM System x3650 M5

Abstract

With the powerful, versatile 2U rack server design, the dual-socket Lenovo System x3650 M5 (E5-2600 v4) server can run even more workloads, 24 x 7, and gain faster business insights. Integrated with Intel Xeon processor E5-2600 v4 product family and industry-leading two-socket storage capacity, the System x3650 M5 delivers exceptional performance. Flexible and scalable internal storage configurations include up to 28x 2.5-inch or 14x 3.5-inch drives with a wide selection of drive sizes and types.

This product guide provides essential pre-sales information to understand the structure of the System x3650 M5 offering, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the System x3650 M5 and consider its use in IT solutions.

Notes:

  • This Product Guide describes currently available models of the Lenovo System x3650 M5 (Machine Type 8871) with the Intel Xeon processor E5-2600 v4 and E5-2600 v3 product families.
  • For withdrawn models of the Lenovo System x3650 M5 (Machine Type 5462) with the Intel Xeon processor E5-2600 v3 product family that are no longer available for ordering, see the following Product Guide: Lenovo System x3650 M5 (Machine Type 5462).

Change History

Changes in the October 17 update:

  • Added 12 TB 3.5-inch NL SAS and NL SATA hot-swap HDDs
  • Added 2.4 TB 2.5-inch SAS hot-swap FIPS SED
  • Removed withdrawn SSDs
  • Updated Lenovo Storage DX8200D and DX8200C part numbers

Introduction

With the powerful, versatile 2U rack server design, the dual-socket Lenovo System x3650 M5 (E5-2600 v4) server (Machine Type 8871) can run even more workloads, 24 x 7, and gain faster business insights. Integrated with Intel Xeon processor E5-2600 v4 product family and industry-leading two-socket storage capacity, the System x3650 M5 delivers exceptional performance. Flexible and scalable internal storage configurations include up to 28x 2.5-inch or 14x 3.5-inch drives with a wide selection of drive sizes and types.

Suggested uses: Database, cloud computing and virtualization, enterprise applications, collaboration/email, business analytics and big data, virtual desktops, and Microsoft RemoteFX applications.

The following figure shows the System x3650 M5.

 

Lenovo System x3650 M5

Did you know?

The System x3650 M5 incorporates energy-smart features for minimized costs and efficient performance. Dual fan zones support operation in up to 40°C environments. The 80 PLUS Titanium power supply units (PSUs) can deliver 96% efficiency at 50% load.

The System x3650 M5 has outstanding memory performance that is achieved by supporting two-RDIMMs-per-channel configurations at speeds up to 12% faster than the Intel specification, while still maintaining world-class reliability.

The System x3650 M5 integrates leadership security and reliability. System x Trusted Platform Assurance, an exclusive set of System x features and practices, establishes a solid security foundation for your workloads. Enterprise-class data protection is provided with optional self-encrypting drives, and advanced diagnostic tools facilitate reduced downtime and costs.

Key features

The System x3650 M5 is a versatile 2U dual-socket business-critical server that offers improved performance and pay-as-you-grow flexibility along with new features that improve server management capability. This powerful system is designed for your most important business applications and cloud deployments.

Combining balanced performance and flexibility, the System x3650 M5 is a great choice for small and medium businesses up to the large enterprise. It can provide outstanding uptime to keep business-critical applications and cloud deployments running safely. Ease of use and comprehensive systems management tools help make deployment easier. Outstanding reliability, availability, and serviceability (RAS) and high-efficiency design improve your business environment and help save operational costs.

Scalability and performance

The System x3650 M5 offers numerous features to boost performance, improve scalability, and reduce costs:

  • Improves productivity by offering superior system performance with the Intel Xeon processor E5-2600 v4 product family with up to 22-core processors, up to 55 MB of L3 cache, up to 2400 MHz memory speeds, and up to 9.6 GT/s QPI interconnect links.
    • Support for up to two processors, 44 cores, and 88 threads allows to maximize the concurrent execution of multithreaded applications.
    • Intelligent and adaptive system performance with energy efficient Intel Turbo Boost Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
    • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
    • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads.
    Note: Also available via CTO is the Intel Xeon processor E5-2600 v3 product family with up to 14-core processors, up to 35 MB of cache, up to 2133 MHz memory speeds, and up to 9.6 GT/s QPI interconnect links.
  • Up to 2400 MHz memory speeds with two DIMMs per channel running at 2400 MHz to help maximize system performance.
  • Up to 1.5 TB of memory capacity with 64 GB load-reduced DIMMs, or LRDIMMs
  • The 12 Gbps SAS internal storage connectivity doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.
  • Flexible and scalable internal storage configurations provide up to 215 TB of storage capacity with 7.68 TB 2.5-inch solid-state drives (SSDs) in a 2U rack form factor.
  • The use of SSDs instead of or along with traditional spinning HDDs can significantly improve I/O performance. An SSD can support a significantly higher number of I/O operations per second (IOPS) than a typical HDD.
  • The server has four integrated Gigabit Ethernet ports and optional 10 Gb Ethernet ports with ML2 adapters.
  • The server offers up to eight PCI Express (PCIe) 3.0 I/O expansion slots plus one dedicated PCIe 3.0 slot for an internal storage controller in a 2U rack form factor.
  • With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5-2600 v4 product family. This helps to dramatically reduce I/O latency and increase overall system performance.

Availability and serviceability

The System x3650 M5 provides many features to simplify serviceability and increase system uptime:

  • Tool-less cover removal provides easy access to upgrades and serviceable parts, such as processors, memory DIMMs, and adapter cards.
  • The server offers hot-swap drives supporting RAID redundancy for data protection and greater system uptime.
  • The server offers redundant hot-swap power supplies and hot-swap redundant fans to provide availability for business-critical applications.
  • The new Next Gen light path diagnostics LCD display panel simplifies servicing, speeds up problem resolution, and helps improve system availability.
  • Proactive Platform Alerts (including PFA and SMART alerts): Processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 storage, flash storage adapters), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures. Alerts can be surfaced through the system IMM to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
  • SSDs offer significantly better reliability than traditional mechanical HDDs for greater uptime.
  • Built-in Integrated Management Module II (IMM2.1) continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failure, to minimize downtime.
  • Built-in diagnostics using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.

Manageability and security

Powerful systems management features simplify local and remote management of the System x3650 M5 and deliver enterprise-class data protection:

  • The server includes an Integrated Management Module II (IMM2.1) to monitor server availability and perform remote management.
  • An integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
  • Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • An integrated Trusted Platform Module (TPM) enables advanced cryptographic functionality such as digital signatures and remote attestation.
  • System x Trusted Platform Assurance, an exclusive set of System x security features and practices, establishes a solid security foundation for workloads by delivering firmware that is securely built, tested, digitally signed and verified prior to execution.
  • The server offers enterprise-class data protection with optional self-encrypting drives.
  • Industry-standard AES NI support offers faster, stronger encryption.
  • Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.

Energy efficiency

The System x3650 M5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:

  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed, to reduce power draw.
  • Low-voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments.
  • Low-voltage 1.2 V DDR4 memory offers energy savings compared to 1.35 V and 1.5 V DDR3 DIMMs.
  • The server uses hexagonal ventilation holes, a part of Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system.
  • Lenovo XClarity Energy Manager provide advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.

Components and connectors

The following figure shows the front of the System x3650 M5 server with up to 16x 2.5-inch drive bays and the Front IO Cage Entry (default).

Figure 2. Front view of the System x3650 M5: 16x 2.5-inch drive bays; Front IO Cage Entry (default)

The following figure shows the front of the System x3650 M5 server with 8x 2.5-inch SAS/SATA drive bays, up to 8x 2.5-inch PCIe drive bays (optional), and the Front IO Cage Entry (default).

Figure 3. Front view of the System x3650 M5: 8x 2.5-inch SAS/SATA and 8x 2.5-inch PCIe drive bays

The following figure shows the front of the System x3650 M5 server with up to 16x 2.5-inch drive bays and the Front IO Cage Standard (optional).

Figure 4. Front view of the System x3650 M5: 16x 2.5-inch drive bays; Front IO Cage Standard (optional)

The following figure shows the front of the System x3650 M5 server with up to 16x 2.5-inch drive bays and the Front IO Cage Advanced (optional).

Figure 5. Front view of the System x3650 M5: 16x 2.5-inch drive bays; Front IO Cage Advanced (optional)

The following figure shows the front of the System x3650 M5 server with up to 24x 2.5-inch drive bays.

Figure 6. Front view of the System x3650 M5: 24x 2.5-inch drive bays

The following figure shows the front of the System x3650 M5 server with 16x 2.5-inch SAS/SATA and 4x 2.5-inch PCIe drive bays.

Figure 7. Front view of the System x3650 M5: 16x 2.5-inch SAS/SATA and 4x 2.5-inch PCIe drive bays

The following figure shows the front of the System x3650 M5 server with 8x 3.5-inch drive bays.

Figure 8. Front view of the System x3650 M5: 8x 3.5-inch drive bays

The following figure shows the front of the System x3650 M5 server with 12x 3.5-inch drive bays.

Figure 9. Front view of the System x3650 M5: 12x 3.5-inch drive bays

The following figure shows the rear of the System x3650 M5 server.

Figure 10. Rear view of the System x3650 M5

The following figure shows the locations of key components inside the System x3650 M5 server.

Specifications
ChipsetIntel C612
DimensionsHeight: 87 mm (3.4 in), width: 434 mm (17.1 in), depth: 755 mm (29.7 in)
Drive BaysUp to 28 SFF SAS/SATA hot-swap drive bays: 8x 2.5" (front) + 8x 2.5" (front) + 8x 2.5" (front) + 2x 2.5" (rear) + 2x 2.5" (rear) Up to 16 LFF+SFF SAS/SATA hot-swap drive bays: 12x 3.5" (front) + 2x 3.5" (rear) + 2x 2.5" (rear) Up to 10 LFF or LFF+SFF SAS/SATA hot-swap drive bays: 8x 3.5" (front) + 2x 3.5" (rear) 8x 3.5" (front) + 2x 2.5" (rear) Up to 8 SFF NVMe PCIe SSD hot-swap + SFF SAS/SATA hot-swap drive bays: 8x 2.5" SAS/SATA (front) + 4x 2.5" NVMe PCIe (front) + 4x 2.5" NVMe PCIe (front) 8x 2.5" SAS/SATA (front) + 8x 2.5" SAS/SATA (front) + 4x 2.5" NVMe PCIe (front)
Hot-Swap ComponentsHard drives, power supplies, and fans.
I/O expansion slotsUp to nine slots. Slots 4, 5, and 9 are the fixed slots on the system planar, and the remaining slots depend on the riser cards installed. The slots are as follows: Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, full-length (PCIe x16 slot is double-wide) Slot 2: PCIe 3.0 x8; full-height, full-length (not present if the slot 1 is PCIe x16) Slot 3: PCIe 3.0 x8 or ML2; full-height, half-length Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar) Slot 5: PCIe 3.0 x8; low profile (vertical slot on system planar) Slot 6: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, full-length (PCIe x16 slot is double-wide) Slot 7: PCIe 3.0 x8; full-height, full-length (not present if the slot 6 is PCIe x16) Slot 8: PCIe 3.0 x8; full-height, half-length Slot 9: PCIe 3.0 x8 (dedicated for an internal storage controller) Slots 5, 6, 7, and 8 require the second processor to be installed.
MemoryUp to 24 DIMM sockets (12 DIMMs per processor; four memory channels per processor with three DIMMs per channel). Support for RDIMMs and LRDIMMs. Memory types cannot be intermixed. Memory speed up to 2400 MHz.
Memory (max) With RDIMMs: Up to 768 GB with 24x 32 GB RDIMMs and two processors With LRDIMMs: Up to 1.5 TB with 24x 64 GB LRDIMMs and two processors
Memory protectionECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory rank sparing.
Network Interfaces 4x integrated RJ-45 Gigabit Ethernet ports (BCM5719). Optional Mezzanine LOM (ML2) slot for dual-port 10 GbE cards with SFP+ or RJ-45 connectors or quad-port GbE cards with RJ-45 connectors. 1x RJ-45 10/100/1000 Mb Ethernet systems management port.
Operating Systems SupportedMicrosoft Windows Server 2008 R2, 2012, 2012 R2, and 2016; Red Hat Enterprise Linux 6 (x64) and 7; SUSE Linux Enterprise Server 11 (x64) and 12; VMware vSphere (ESXi) 5.5, 6.0, and 6.5.
Optical driveOne for models with 8x 3.5" or up to 16x 2.5" drive bays (models with 24x 2.5" or 12x 3.5" drive bays do not support an internal optical drive). Support for DVD-ROM or Multiburner.
Power SupplyUp to two redundant hot-swap 550 W, 750 W, or 900 W (100-240V), or 1500 W (200-240V) High Efficiency Platinum AC power supplies, or 750 W or 1300 W (200-240V) High Efficiency Titanium AC power supplies, or 900 W High Efficiency -48 V DC power supplies.
ProcessorUp to two processors of the Intel Xeon processor E5-2600 v4 product family: Up to 22 cores (2.4 GHz core speeds) Up to 3.5 GHz core speeds (4 cores) Two QPI links up to 9.6 GT/s each Up to 55 MB cache Up to 2400 MHz memory speed Up to two processors of the Intel Xeon processor E5-2600 v3 product family (CTO only): Up to 14 cores with up to 2.6 GHz core speeds Two QPI links up to 9.6 GT/s each Up to 35 MB cache Up to 2133 MHz memory speed
SecurityPower-on password, administrator's password, Trusted Platform Module (TPM) 1.2 or 2.0 (configurable UEFI setting). Optional lockable front bezel.
Service and supportOptional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for System x hardware and some System x third-party applications.
Storage Up to 183 TB with 14x 12 TB 3.5" NL SAS or SATA HDDs and 2x 7.68 TB 2.5" SAS SSDs Up to 215 TB with 28x 7.68 TB 2.5" SAS SSDs Up to 56 TB with 28x 2 TB 2.5" NL SATA HDDs Up to 67.2 TB with 28x 2.4 TB 2.5" SAS HDDs Up to 30.7 TB with 8x 3.84 TB NVMe PCIe SSDs Intermix of SAS, SATA, and PCIe drives is supported.
Storage Controller 12 Gb SAS/6 Gb SATA RAID: RAID 0, 1, 10 with M1215 or M5210. Optional upgrade to RAID 5, 50 is available for M1215. Optional upgrade to RAID 5, 50 is available for M5210 (zero-cache; 1 GB non-backed cache; 1 GB, 2 GB or 4 GB flash-backed cache). Optional upgrade to RAID 6, 60 is available for M5210 (requires a cache upgrade). Optional SSD Caching and Performance Accelerator upgrades are available for M5210. 12 Gb SAS/6 Gb SATA non-RAID: N2215 HBA
Systems ManagementUEFI, Integrated Management Module II (IMM2.1) based on Renesas SH7758, Predictive Failure Analysis, light path diagnostics, Automatic Server Restart, ToolsCenter, XClarity Administrator, XClarity Energy Manager. Optional IMM2.1 Advanced Upgrade software feature for remote presence (graphics, keyboard and mouse, virtual media).
Tape drive typesNone.
VideoMatrox G200eR2 with 16 MB memory integrated into the IMM2.1. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors.
WeightMinimum configuration: 19 kg (41.8 lb), maximum: 34 kg (74.8 lb)
WarrantyThree-year customer-replaceable unit and onsite limited warranty with 9x5 next business day.

Write a review

Note: HTML is not translated!
    Bad           Good

Standard models

The following table lists the standard models of the System x3650 M5.

Product availability: Standard models of the x3650 M5 (E5-2600 v4) are not available in North America.

Table 2. Standard models (F = Flash backup)

Model number*Intel Xeon processor**
(2 maximum)
Memory RDIMM#RAIDDrive bays
(std / max)
DrivesNICI/O slots
(std / max)§
Optical drive§§LCD
display
Power supply
(std / max)***
Models announced March 2016
8871A2x1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W1x 8GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871B2x1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W1x 8GBM12158x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 550W HS / 2
8871C2x1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871C4x1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM12158x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 550W HS / 2
8871D2x1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM5210 1GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871D4x1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM5210 1GB (F)12x 3.5" HS / 16‡Open bay4x GbE3 / 9NoneNone1x 750W HS / 2
8871F2x1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM5210 1GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871F4x1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM5210 1GB (F)8x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 750W HS / 2
8871G2x1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W1x 16GBM5210 1GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871N2x1x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W1x 16GBM5210 2GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9OptionIncluded1x 750W HS / 2
8871R2x1x E5-2667 v4 8C 3.2GHz 25MB 2400MHz 135W1x 16GBM5210 2GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9OptionIncluded1x 900W HS / 2
8871J2x1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W1x 16GBM5210 2GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871L2x1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871Q2x1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W1x 16GBM5210 2GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9OptionIncluded1x 900W HS / 2

* x in the Model number represents a country-specific letter. Ask a Lenovo representative for specifics.
** Processor details: Processor quantity and model, cores, core speed, cache, memory speed, and thermal design power (TDP).
§ With one processor, only two fixed onboard PCIe slots (Slots 4 and 9) can be used (Slot 5 requires the second processor). An internal storage controller occupies PCIe slot 9.
§§ An optional optical drive requires the ODD Cable (00AL956).
*** The power supplies are 80 PLUS Platinum certified.
# Unless otherwise specified in a footnote, the DIMMs installed are x4 RDIMMs.
^ An optional optical drive requires the Front IO Cage Standard (00YD070) or Advanced (00YD002).
^^ An optional LCD display is included in the Front IO Cage Advanced (00YD002).
† The maximum number of the drive bays (10) includes 8x 3.5" front bays and 2x 3.5" or 2x 2.5" rear bays.
‡ The maximum number of the drive bays (16) includes 12x 3.5" front bays, 2x 3.5" rear bays, and 2x 2.5" rear bays.

The standard models of the System x3650 M5 that are listed in Table 2 are shipped with the following items:

  • Rack Installation Guide
  • Electronic Publications Flyer
  • System x Enterprise Slides Kit

TopSeller models

The following table lists the TopSeller models of the System x3650 M5.

Table 3. TopSeller models (F = Flash backup)

Model numberIntel Xeon processor***
(2 maximum)
Memory RDIMM#RAID /
HBA
Drive bays
(std / max)
DrivesNICI/O slots
(std / max)§
Optical drive§§LCD
display
Power supply
(std / max)**
TopSeller - United States, Canada
8871KAU1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W1x 16GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871KBU1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W1x 16GBM12158x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 900W HS / 2
887110R*1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W4x 8GB##N221514x 3.5" HS / 14Open bay4x GbE6 / 9NoneNone2x 900W HS / 2
8871KCU1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W1x 16GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871KDU1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W1x 16GBM12158x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 900W HS / 2
887116J1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W1x 16GBM5210 2GB (F)12x 3.5" HS / 16‡Open bay4x GbE3 / 9NoneNone2x 900W HS / 2
887116I1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W1x 16GBM5210 2GB (F)24x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone2x 900W HS / 2
8871KEU1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871KFU1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM12158x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 900W HS / 2
887116A1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM521024x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871K8U1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871KGU1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871KHU1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM52108x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 900W HS / 2
887116B1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM521024x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871KQU1x E5-2637 v4 4C 3.5GHz 15MB 2400MHz 135W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871KJU1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871KKU1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM52108x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 900W HS / 2
8871K4U1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
887116F1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 32GBM521024x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871K7U2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W2x 32GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^2x 900W HS / 2
887110W*1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W4x 8GB#N221514x 3.5" HS / 14Open bay4x GbE6 / 9NoneNone2x 900W HS / 2
8871KXU2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W4x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^2x 900W HS / 2
887110T*2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W8x 16GBN221514x 3.5" HS / 14Open bay4x GbE6 / 9NoneNone2x 900W HS / 2
88711A2~2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W8x 16GBN221514x 3.5" HS / 14Open bay4x GbE5 / 9NoneNone2x 1300W HS / 2
8871KLU1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
887110P1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871KVU2x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W8x 16GBM52108x 2.5" HS / 202x 240GB SSD4x GbE3 / 9Option^Option^^2x 900W HS / 2
8871KMU1x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
887116C1x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W1x 16GBM521024x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871K3U2x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W2x 32GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^2x 900W HS / 2
8871KYU2x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W4x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^2x 900W HS / 2
8871KZU2x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W4x 16GBM5210 1GB (F)12x 3.5" HS / 16‡Open bay4x GbE3 / 9NoneNone2x 900W HS / 2
8871KRU1x E5-2667 v4 8C 3.2GHz 25MB 2400MHz 135W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871KNU1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871K5U1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
887116G1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W1x 32GBM521024x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871KPU1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
887116D1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W1x 16GBM521024x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871KUU2x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W2x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^2x 900W HS / 2
8871KWU2x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W8x 16GBM52108x 2.5" HS / 202x 240GB SSD4x GbE3 / 9Option^Option^^2x 900W HS / 2
88711A1~2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W8x 32GBN22158x 2.5" HS / 26Open bay4x GbE5 / 9NoneNone2x 1300W HS / 2
887110U*2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W8x 16GBN221514x 3.5" HS / 14Open bay4x GbE6 / 9NoneNone2x 900W HS / 2
88711A3~2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W8x 16GBN221514x 3.5" HS / 14Open bay4x GbE5 / 9NoneNone2x 1300W HS / 2
887110V*2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W8x 32GBN221514x 3.5" HS / 14Open bay4x GbE6 / 9NoneNone2x 900W HS / 2
88711A4~2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W8x 32GBN221514x 3.5" HS / 14Open bay4x GbE5 / 9NoneNone2x 1300W HS / 2
887110S*2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W8x 32GBN221524x 2.5" HS / 26Open bay4x GbE6 / 9NoneNone2x 900W HS / 2
8871KSU1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871K6U1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
887116H1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W1x 32GBM521024x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871KTU1x E5-2699 v4 22C 2.2GHz 55MB 2400MHz 145W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
TopSeller - Europe, Middle East and Africa
8871EBG1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W1x 8GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871ECG1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871EEG1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871EFG1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 202x 10K 300GB4x GbE3 / 9Option^Option^^2x 550W HS / 2
8871EJG1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871ENG1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871EWG1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 750W HS / 2
8871EAG1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM52108x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 750W HS / 2
887116L1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM5210 2GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871EDG1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM12158x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871E6G1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871EGG1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871EKG1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871EYG1x E5-2637 v4 4C 3.5GHz 15MB 2400MHz 135W1x 16GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 1500W HS / 2
8871EHG1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871ELG1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871EPG1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871EXG1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W1x 16GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871E5G1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 550W HS / 2
8871EMG1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871EQG1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871SCG1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871SDG1x E5-2667 v4 8C 3.2GHz 25MB 2400MHz 135W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871ERG1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871ETG1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871SAG1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871ESG1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
8871EUG1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2
8871SBG1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871SEG1x E5-2698 v4 20C 2.2GHz 50MB 2400MHz 135W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
8871EVG1x E5-2699 v4 22C 2.2GHz 55MB 2400MHz 145W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 1500W HS / 2
8871SFG1x E5-2699 v4 22C 2.2GHz 55MB 2400MHz 145W1x 32GBM52108x 2.5" HS / 28Open bay4x GbE3 / 9NoneNone1x 900W HS / 2
TopSeller - Japan
8871E7J1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W1x 8GBM12158x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 550W HS / 2
8871E2J1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W1x 8GBM5210 1GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9OptionIncluded1x 550W HS / 2
8871E3J1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W1x 8GBM5210 1GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9OptionIncluded1x 550W HS / 2
8871E4J1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 8GBM5210 1GB (F)8x 2.5" HS / 20Open bay4x GbE3 / 9OptionIncluded1x 550W HS / 2
TopSeller - Australia and New Zealand
887110X1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W1x 8GBM12158x 3.5" HS / 10†Open bay4x GbE3 / 9OptionIncluded1x 550W HS / 2
887110Z1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 750W HS / 2
88711A01x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W1x 16GBM52108x 2.5" HS / 20Open bay4x GbE3 / 9Option^Option^^1x 900W HS / 2

*** Processor details: Processor quantity and model, cores, core speed, cache, memory speed, and thermal design power (TDP).
§ With one processor, only two fixed onboard PCIe slots (Slots 4 and 9) can be used (Slot 5 requires the second processor). An internal storage controller occupies PCIe slot 9.
§§ An optional optical drive requires the ODD Cable (00AL956).
** The power supplies are 80 PLUS Platinum certified.
† The maximum number of the drive bays (10) includes 8x 3.5" front bays and 2x 2.5" rear bays.
‡ The maximum number of the drive bays (16) includes 12x 3.5" front bays, 2x 3.5" rear bays, and 2x 2.5" rear bays.
* This model includes the SD Media Adapter with two blank SD cards (00ML706), PCIe Riser 1 (2 x8 FH/FL + 1 x8 FH/HL Slots) (00KA498), and IMM Advanced Upgrade (90Y3901).
# Unless otherwise specified in a footnote, the DIMMs installed are x4 RDIMMs.
## 8 GB 2Rx8 memory RDIMM (46W0825)
^ An optional optical drive requires the Front IO Cage Standard (00YD070) or Advanced (00YD002).
^^ An optional LCD display is included in the optional Front IO Cage Advanced (00YD002).
~ This model includes the dual-rotor fan base, SD Media Adapter with two blank SD cards (00ML706), PCIe Riser 1 (1 x16 FH/FL + 1 x8 FH/HL Slots) (00KA489), and IMM Advanced Upgrade (90Y3901).

The TopSeller models of the System x3650 M5 listed in this section are shipped with the following items:

  • Rack Installation Guide
  • Electronic Publications Flyer
  • System x Enterprise Slides Kit
  • One or two 2.8 m IEC 320-C13 to C14 rack power cords (matches the quantity of power supplies)

Processors

The System x3650 M5 supports up to two processors of the Intel Xeon processor E5-2600 v4 product family. Also, support for the Intel Xeon processor E5-2600 v3 product family is available via CTO only. The following tables list the specifications of the processors for the System x3650 M5.

Table 4. E5-2600 v4 specifications (HT = Hyper-Threading, TB = Turbo Boost, VT = Virtualization Technology)

Processor
model
Core frequency
(Base / TB Max)
Number
of cores /
threads
CacheMax DDR4
frequency
QPI
speed
TDPHTTBVT-xVT-d
E5-2603 v41.7 GHz6 / 615 MB1866 MHz6.4 GT/s85 WNoNoYesYes
E5-2608L v41.6 GHz8 / 1620 MB1866 MHz6.4 GT/s50 WYesNoYesYes
E5-2609 v41.7 GHz8 / 820 MB1866 MHz6.4 GT/s85 WNoNoYesYes
E5-2618L v42.2 / 3.2 GHz10 / 2025 MB2133 MHz8.0 GT/s75 WYesYesYesYes
E5-2620 v42.1 / 3 GHz8 / 1620 MB2133 MHz8.0 GT/s85 WYesYesYesYes
E5-2623 v42.6 / 3.2 GHz4 / 810 MB2133 MHz8.0 GT/s85 WYesYesYesYes
E5-2628L v41.9 / 2.4 GHz12 / 2430 MB2133 MHz8.0 GT/s75 WYesYesYesYes
E5-2630 v42.2 / 3.1 GHz10 / 2025 MB2133 MHz8.0 GT/s85 WYesYesYesYes
E5-2630L v41.8 / 2.9 GHz10 / 2025 MB2133 MHz8.0 GT/s55 WYesYesYesYes
E5-2637 v43.5 / 3.7 GHz4 / 815 MB2400 MHz9.6 GT/s135 WYesYesYesYes
E5-2640 v42.4 / 3.4 GHz10 / 2025 MB2133 MHz8.0 GT/s90 WYesYesYesYes
E5-2643 v43.4 / 3.7 GHz6 / 1220 MB2400 MHz9.6 GT/s135 WYesYesYesYes
E5-2648L v41.8 / 2.5 GHz14 / 2835 MB2400 MHz9.6 GT/s75 WYesYesYesYes
E5-2650 v42.2 / 2.9 GHz12 / 2430 MB2400 MHz9.6 GT/s105 WYesYesYesYes
E5-2650L v41.7 / 2.5 GHz14 / 2835 MB2400 MHz9.6 GT/s65 WYesYesYesYes
E5-2658 v42.3 / 2.8 GHz14 / 2835 MB2400 MHz9.6 GT/s105 WYesYesYesYes
E5-2660 v42 / 3.2 GHz14 / 2835 MB2400 MHz9.6 GT/s105 WYesYesYesYes
E5-2667 v43.2 / 3.6 GHz8 / 1625 MB2400 MHz9.6 GT/s135 WYesYesYesYes
E5-2680 v42.4 / 3.3 GHz14 / 2835 MB2400 MHz9.6 GT/s120 WYesYesYesYes
E5-2683 v42.1 / 3 GHz16 / 3240 MB2400 MHz9.6 GT/s120 WYesYesYesYes
E5-2690 v42.6 / 3.5 GHz14 / 2835 MB2400 MHz9.6 GT/s135 WYesYesYesYes
E5-2695 v42.1 / 3.3 GHz18 / 3645 MB2400 MHz9.6 GT/s120 WYesYesYesYes
E5-2697 v42.3 / 3.6 GHz18 / 3645 MB2400 MHz9.6 GT/s145 WYesYesYesYes
E5-2697A v42.6 / 3.6 GHz16 / 3240 MB2400 MHz9.6 GT/s145 WYesYesYesYes
E5-2698 v42.2 / 3.6 GHz20 / 4050 MB2400 MHz9.6 GT/s135 WYesYesYesYes
E5-2699 v42.2 / 3.6 GHz22 / 4455 MB2400 MHz9.6 GT/s145 WYesYesYesYes
E5-2699R v42.2 / 3.6 GHz22 / 4455 MB2400 MHz9.6 GT/s145 WYesYesYesYes
E5-2699A v42.4 / 3.6 GHz22 / 4455 MB2400 MHz9.6 GT/s145 WYesYesYesYes

Table 5. E5-2600 v3 specifications (HT = Hyper-Threading, TB = Turbo Boost, VT = Virtualization Technology)

Processor
model
Core frequency
(Base / TB Max)
Number
of cores /
threads
CacheMax DDR4
frequency
QPI
speed
TDPHTTBVT-xVT-d
E5-2603 v31.6 GHz6 / 615 MB1600 MHz6.4 GT/s85 WNoNoYesYes
E5-2609 v31.9 GHz6 / 615 MB1600 MHz6.4 GT/s85 WNoNoYesYes
E5-2620 v32.4 / 3.2 GHz6 / 1215 MB1866 MHz8 GT/s85 WYesYesYesYes
E5-2630 v32.4 / 3.2 GHz8 / 1620 MB1866 MHz8 GT/s85 WYesYesYesYes
E5-2640 v32.6 / 3.4 GHz8 / 1620 MB1866 MHz8 GT/s90 WYesYesYesYes
E5-2650 v32.3 / 3 GHz10 / 2025 MB2133 MHz9.6 GT/s105 WYesYesYesYes
E5-2660 v32.6 / 3.3 GHz10 / 2025 MB2133 MHz9.6 GT/s105 WYesYesYesYes
E5-2670 v32.3 / 3.1 GHz12 / 2430 MB2133 MHz9.6 GT/s120 WYesYesYesYes
E5-2680 v32.5 / 3.3 GHz12 / 2430 MB2133 MHz9.6 GT/s120 WYesYesYesYes
E5-2690 v32.6 / 3.5 GHz12 / 2430 MB2133 MHz9.6 GT/s135 WYesYesYesYes
E5-2695 v32.3 / 3.3 GHz14 / 2835 MB2133 MHz9.6 GT/s120 WYesYesYesYes
E5-2697 v32.6 / 3.6 GHz14 / 2835 MB2133 MHz9.6 GT/s145 WYesYesYesYes

For System x3650 M5 server models that come standard with one processor, the second processor can be ordered, if required (see the following table for ordering information). The second processor must be of the same model as the first processor. The second processor option includes two system fans.

Table 6. Processor options

DescriptionPart numberFeature codes*
Intel Xeon Processor E5-2600 v4 product family
Intel Xeon Processor E5-2603 v4 6C 1.7GHz 15MB Cache 1866MHz 85W00YJ203ATEU / ATFK
Intel Xeon Processor E5-2608L v4 8C 1.6GHz 20MB Cache 1866MHz 50W00YJ219ATFA / ATG1
Intel Xeon Processor E5-2609 v4 8C 1.7GHz 20MB Cache 1866MHz 85W00YJ196ATEM / ATFC
Intel Xeon Processor E5-2618L v4 10C 2.2GHz 25MB Cache 2133MHz 75W00YJ218ATF9 / ATG0
Intel Xeon Processor E5-2620 v4 8C 2.1GHz 20MB Cache 2133MHz 85W00YJ195ATEL / ATFB
Intel Xeon Processor E5-2623 v4 4C 2.6GHz 10MB Cache 2133MHz 85W00YJ217ATF8 / ATFZ
Intel Xeon Processor E5-2628L v4 12C 1.9GHz 30MB Cache 2133MHz 75W00YJ215ATF6 / ATFX
Intel Xeon Processor E5-2630 v4 10C 2.2GHz 25MB Cache 2133MHz 85W00YJ198ATEP / ATFE
Intel Xeon Processor E5-2630L v4 10C 1.8GHz 25MB Cache 2133MHz 55W00YJ209ATF0 / ATFR
Intel Xeon Processor E5-2637 v4 4C 3.5GHz 15MB Cache 2400MHz 135W00YJ208ATEZ / ATFQ
Intel Xeon Processor E5-2640 v4 10C 2.4GHz 25MB Cache 2133MHz 90W00YJ199ATEQ / ATFF
Intel Xeon Processor E5-2643 v4 6C 3.4GHz 20MB Cache 2400MHz 135W00YJ207ATEY / ATFP
Intel Xeon Processor E5-2648L v4 14C 1.8GHz 35MB Cache 2400MHz 75W00YJ213ATF4 / ATFV
Intel Xeon Processor E5-2650 v4 12C 2.2GHz 30MB Cache 2400MHz 105W00YJ197ATEN / ATFD
Intel Xeon Processor E5-2650L v4 14C 1.7GHz 35MB Cache 2400MHz 65W00YJ210ATF1 / ATFS
Intel Xeon Processor E5-2658 v4 14C 2.3GHz 35MB Cache 2400MHz 105W00YJ214ATF5 / ATFW
Intel Xeon Processor E5-2660 v4 14C 2.0GHz 35MB Cache 2400MHz 105W00YJ205ATEW / ATFM
Intel Xeon Processor E5-2667 v4 8C 3.2GHz 25MB Cache 2400MHz 135W00YJ201ATES / ATFH
Intel Xeon Processor E5-2680 v4 14C 2.4GHz 35MB Cache 2400MHz 120W00YJ202ATET / ATFJ
Intel Xeon Processor E5-2683 v4 16C 2.1GHz 40MB Cache 2400MHz 120W00YJ216ATF7 / ATFY
Intel Xeon Processor E5-2690 v4 14C 2.6GHz 35MB Cache 2400MHz 135W00YJ200ATER / ATFG
Intel Xeon Processor E5-2695 v4 18C 2.1GHz 45MB Cache 2400MHz 120W00YJ206ATEX / ATFN
Intel Xeon Processor E5-2697 v4 18C 2.3GHz 45MB Cache 2400MHz 145W00YJ204ATEV / ATFL
Intel Xeon Processor E5-2697A v4 16C 2.6GHz 40MB Cache 2400MHz 145W01GT188AUDY / AUE0
Intel Xeon Processor E5-2698 v4 20C 2.2GHz 50MB Cache 2400MHz 135W00YJ212ATF3 / ATFU
Intel Xeon Processor E5-2699 v4 22C 2.2GHz 55MB Cache 2400MHz 145W00YJ211ATF2 / ATFT
Intel Xeon Processor E5-2699R v4 22C 2.2GHz 55MB Cache 2400MHz 145W01GV376AVHA / AVHJ
Intel Xeon Processor E5-2699A v4 22C 2.4GHz 55MB Cache 2400MHz 145W01GV377AVHB / AVHK
Intel Xeon Processor E5-2600 v3 product family
Intel Xeon Processor E5-2603 v3 6C 1.6GHz 15MB 1600MHz 85W00FK640A5EB / A5EG
Intel Xeon Processor E5-2609 v3 6C 1.9GHz 15MB 1600MHz 85W00FK641A5EC / A5EH
Intel Xeon Processor E5-2620 v3 6C 2.4GHz 15MB 1866MHz 85W00FK642A5ED / A5EJ
Intel Xeon Processor E5-2630 v3 8C 2.4GHz 20MB 1866MHz 85W00FK643A5EE / A5EK
Intel Xeon Processor E5-2640 v3 8C 2.6GHz 20MB 1866MHz 90W00FK644A5GT / A5EL
Intel Xeon Processor E5-2650 v3 10C 2.3GHz 25MB 2133MHz 105W00FK645A5GU / A5EM
Intel Xeon Processor E5-2660 v3 10C 2.6GHz 25MB 2133MHz 105W00KG839ASDA / ASDM
Intel Xeon Processor E5-2670 v3 12C 2.3GHz 30MB 2133MHz 120W00FK647A5GV / A5EN
Intel Xeon Processor E5-2680 v3 12C 2.5GHz 30MB 2133MHz 120W00FK648A5GW / A5EP
Intel Xeon Processor E5-2690 v3 12C 2.6GHz 30MB 2133MHz 135W00FK649A5GX / A5EQ
Intel Xeon Processor E5-2697 v3 14C 2.6GHz 35MB 2133MHz 145W00KG843ASDE / ASDR

* The first feature code is for the first processor; the second feature code is for the second processor.

Memory

The System x3650 M5 supports TruDDR4 memory. TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility tested and tuned on every System x server to maximize performance and reliability.

TruDDR4 memory has a unique signature programmed into the DIMM, which enables System x servers to verify whether the memory installed is qualified and supported. Because TruDDR4 memory is authenticated, certain extended memory performance features can be enabled to extend performance over industry standards. From a service and support standpoint, System x memory automatically assumes the system's warranty, and service and support provided worldwide.

The System x3650 M5 supports up to 12 DIMMs with one processor and up to 24 DIMMs when two processors are installed. Each processor has four memory channels, and there are three DIMMs per channel.

The following rules apply when selecting the memory configuration:

  • The server supports RDIMMs and LRDIMMs.
  • Mixing different types of memory (RDIMMs and LRDIMMs) is not supported.
  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of:
    • Memory speed that is supported by the specific processor.
    • Memory speed for selected quantity of DIMMs per channel.
    Note: Maximum memory speed can be achieved when Max performance mode is enabled in UEFI.

The following memory protection technologies are supported:

  • ECC
  • Chipkill (for x4-based memory DIMMs)
  • Memory mirroring
  • Memory rank sparing

Chipkill works only in independent channel mode (the default operational mode) and supports only x4-based memory DIMMs.

If memory mirroring is used, then DIMMs must be installed in pairs (a minimum of one pair per each processor), and both DIMMs in a pair must be identical in type and size.

If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs installed.

Chipkill, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on a server, and it is a system-wide setting.

System x engineering tested and validated system designs that support memory speeds beyond Intel memory specifications, which provides benefits for workloads that require memory speed and density. System x TruDDR4 memory is fully supported up to the rated speeds that are shown in the following table. Table cells highlighted with a gray background indicate when the DIMMs are allowed to operate at a higher speed than Intel specifications define.

Table 7. System x3650 M5 maximum memory speeds and capacities

DIMMs per channel
RDIMM
LR-DIMM
Memory bus speedMaximum capacity*Memory bus speedMaximum capacity*
Intel Xeon processor E5-2600 v4 product family
1 DPC2400 MHz256 GB (8x 32 GB)2400 MHz512 GB (8x 64 GB)
2 DPC2400 MHz512 GB (16x 32 GB)2400 MHz1,024 GB (16x 64 GB)
3 DPC1866 MHz768 GB (24x 32 GB)2133 MHz1,536 GB (24x 64 GB)
Intel Xeon processor E5-2600 v3 product family
1 DPC2133 MHz256 GB (8x 32 GB)2133 MHz512 GB (8x 64 GB)
2 DPC2133 MHz512 GB (16x 32 GB)2133 MHz1,024 GB (16x 64 GB)
3 DPC1866 MHz768 GB (24x 32 GB)1866 MHz1,536 GB (24x 64 GB)

* Maximum memory capacity is achieved with two processors installed. With one processor, the capacity is a half of what is shown.

The following table lists memory options available for the System x3650 M5 server.

Table 8. Memory options

DescriptionPart numberFeature codeMaximum supported*
RDIMMs - 2400 MHz
8GB TruDDR4 Memory (1Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM46W0821ATC812 / 24
8GB TruDDR4 Memory (2Rx8, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM46W0825ATC912 / 24
16GB TruDDR4 Memory (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM46W0829ATCA12 / 24
16GB TruDDR4 Memory (2Rx8, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM01KN301AVP012 / 24**
32GB TruDDR4 Memory (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM46W0833ATCB12 / 24
LRDIMMs - 2400 MHz
64GB TruDDR4 Memory (4Rx4, 1.2V) PC4-19200 PC4 2400MHz LP LRDIMM46W0841ATGG12 / 24

* One processor / two processors.
** Not supported with the Intel Xeon processor E5-2600 v3 product family.

Internal storage

The System x3650 M5 server supports the following drive bay configurations:

  1. Models with 8x 2.5-inch SAS/SATA hot-swap drive bays that can be upgraded to the following drive bay configurations:
    1. 8x 2.5-inch (front) + 2x 2.5-inch (rear) SAS/SATA hot-swap + 4x 2.5-inch PCIe SSD (front) hot-swap drive bays
    2. 8x 2.5-inch SAS/SATA (front) + 8x 2.5-inch PCIe SSD (front) hot-swap drive bays
    3. 16x 2.5-inch SAS/SATA (front) + 4x 2.5-inch PCIe SSD (front) hot-swap drive bays
    4. 16x 2.5-inch (front) + 2x 2.5-inch (rear) + 2x 2.5-inch (rear) SAS/SATA hot-swap drive bays
  2. Storage dense models with 8x 2.5-inch SAS/SATA hot-swap drive bays that can be upgraded to up to 28x (up to 24 on the front; up to 4 on the rear) 2.5-inch SAS/SATA hot-swap drive bays
  3. Models with 8x 3.5-inch SAS/SATA hot-swap drive bays that can be upgraded to the following drive bay configurations (for a total of 10 drive bays):
    1. 8x 3.5-inch (front) + 2x 3.5-inch (rear) SAS/SATA hot-swap drive bays
    2. 8x 3.5-inch (front) + 2x 2.5-inch (rear) SAS/SATA hot-swap drive bays
  4. Models with 12x 3.5-inch SAS/SATA hot-swap drive bays that can be upgraded to up to 16x SAS/SATA hot-swap drive bays: 12x 3.5-inch (front) + 2x 3.5-inch (rear) + 2x 2.5-inch (rear)

The following figure shows the SAS/SATA drive bay configurations.

Internal SAS/SATA drive configurations
Figure 12. Internal SAS/SATA drive bay configurations

The following figure shows the SAS/SATA and PCIe drive bay configurations.

Internal SAS/SATA and PCIe SSD drive configurations
Figure 13. Internal SAS/SATA and PCIe drive bay configurations

8x 3.5-inch drive bay models of the System x3650 M5 have one optical disk drive (ODD) bay. For models with up to 16x 2.5-inch drive bays, the optional Front IO Cage Standard or Advanced provides one optical drive bay and 3x USB 2.0 ports. In addition, the Front IO Cage Advanced provides an LCD display. These options are listed in the following table.

Table 9. Front panel options

DescriptionPart numberFeature codeMaximum supported
x3650 M5 Front IO Cage Entry (1x USB only)None*ATE51
x3650 M5 Front IO Cage Std. (3x USB, Optional LCD/Optical drive)00YD070ATE61
x3650 M5 Front IO Cage Adv. (3x USB, LCD, Optional Optical Drive)00YD002**None**1

* Included with select standard and TopSeller models or configurable via CTO.
** The Front IO Cage Advanced part number (00YD002) includes the Front IO Cage Standard (feature code ATE6), System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8), and LCD display (feature code A4VH). If configured via CTO, the LCD display (feature code A4VH) is derived when the Front IO Cage Standard (feature code ATE6) and System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8) are selected.

The following table shows the internal storage options available for the System x3650 M5 server.

Table 10. Internal storage options

DescriptionPart numberFeature codeMaximum supported
Base drive kits (factory installed)*
System x3650 M5 8x 2.5" HS HDD Assembly Kit (Single RAID)None*A5G61
System x3650 M5 16x 2.5" HS HDD Assembly Kit (Single RAID)None*A5GF1
System x3650 M5 16x 2.5" HS HDD Assembly Kit (Dual RAID)None*A5GG1
System x3650 M5 24x 2.5" HS HDD Assembly Kit (Single RAID)None*A5G71
System x3650 M5 24x 2.5" HS HDD Assembly Kit (Dual RAID)None*A5TN1
System x3650 M5 24x 2.5" HS HDD Assembly Kit (Triple RAID)None*A5G81
System x3650 M5 8x 3.5" HS HDD Assembly KitNone*ATEG1
System x3650 M5 12x 3.5" HS HDD Assembly KitNone*A5GE1
System x3650 M5 Rear 2x 2.5" HDD Kit (Independent RAID)None*A5GH2
System x3650 M5 Rear 2x 3.5" HDD Kit (Cascaded)**None*A5GL1
System x3650 M5 Rear 2x 3.5" HDD Kit (Independent RAID)None*A5GK1
System x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade KitNone*ASRL2
Upgrade drive kits (require the base drive kit)
System x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit with Expander00FK661AS442
System x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit00FK676AS452
System x3650 M5 Rear 2x 2.5" HDD Kit00FK658AS422
System x3650 M5 Rear 2x 3.5" HDD Kit00FK659AS431
System x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade Kit00FK677None***2

* Base drive kits are always factory-installed in either standard or custom (CTO or Special Bid) models, and they might not have an option part number assigned.
** The 2x 3.5-inch Rear HDD Kit is connected to the SAS expander on the 12-drive backplane, that is, to the same storage controller as 12 drive bays on the front.
*** This Upgrade kit can be installed as a field upgrade only, and it includes 1x NVMe PCIe SSD Upgrade Kit (feature code ASRL) and 2x PCIe SSD Extender Adapters (feature code AS95).

The following table lists possible factory-installed internal storage configurations and field upgrades.

Table 11. Internal storage configurations (FC=Feature Code, PN=Part Number)

Drive bay configurationStorage
controller*
Drive kits required
Front drive bays
8x 2.5-in. SAS/SATA
hot-swap (front)
1x RAID or HBA
(8 drives)
Factory installed:
  • 1x x3650 M5 8x 2.5" HS HDD Assembly Kit (Single RAID) (FC A5G6)
16x 2.5-in. SAS/SATA
hot-swap (front)
1x RAID or HBA
(16 drives)
Factory installed:
  • 1x x3650 M5 16x 2.5" HS HDD Assembly Kit (Single RAID) (FC A5GF)
Field upgrade for 8x 2.5-inch HS drive models:
  • 1x x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit with Expander (PN 00FK661)
2x RAID or HBA
(8+8 drives)
Factory installed:
  • 1x x3650 M5 16x 2.5" HS HDD Assembly Kit (Dual RAID) (FC A5GG)
Field upgrade for 8x 2.5-inch HS drive bay models:
  • 1x x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit (PN 00FK676)
24x 2.5-in. SAS/SATA
hot-swap (front)
1x RAID or HBA
(24 drives)
Factory installed:
  • 1x x3650 M5 24x 2.5" HS HDD Assembly Kit (Single RAID) (FC A5G7)
Field upgrade for 16 (8+8)x 2.5-inch HS drive models:
  • 1x x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit with Expander (PN 00FK661)
2x RAID or HBA
(16+8 drives)
Factory installed:
  • 1x x3650 M5 24x 2.5" HS HDD Assembly Kit (Dual RAID) (FC A5TN)
Field upgrade for 16 (8+8)x 2.5-inch HS drive models:
  • 1x x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit with Expander (PN 00FK661)
Field upgrade for 16 (16)x 2.5-inch HS drive models:
  • 1x x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit (PN 00FK676)
3x RAID or HBA
(8+8+8 drives)
Factory installed:
  • 1x x3650 M5 24x 2.5" HS HDD Assembly Kit (Triple RAID) (FC A5G8)
Field upgrade for 16 (8+8)x 2.5-inch HS drive models:
  • 1x x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit (PN 00FK676)
4x 2.5-in. PCIe SSD
hot-swap (front)
2x PCIe
Extenders#
(2+2)
Factory installed:
  • 1x x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade Kit (FC ASRL)**
Field upgrade for 8x 2.5-inch HS drive models:
  • 1x x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade Kit (PN 00FK677)
8x 2.5-in. PCIe SSD
hot-swap (front)
4x PCIe
Extenders#
(2+2+2+2)
Factory installed:
  • 2x x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade Kit (FC ASRL)##
Field upgrade for 8x 2.5-inch HS drive models:
  • 2x x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade Kit (PN 00FK677)
8x 3.5-in. SAS/SATA
hot-swap (front)
1x RAID or HBA
(8 drives)
Factory installed:
  • 1x x3650 M5 8x 3.5" HS HDD Assembly Kit (FC ATEG)
12x 3.5-in. SAS/SATA
hot-swap (front)
1x RAID or HBA
(12 drives)
Factory installed:
  • 1x x3650 M5 12x 3.5" HS HDD Assembly Kit (FC A5GE)
Rear drive bays
2x 2.5-in. SAS/SATA
hot-swap (rear)

1x M1215
(2 drives)

Factory installed:
  • 1x x3650 M5 Rear 2x 2.5" HDD Kit (Independent RAID) (FC A5GH)
Field upgrade for 2.5-inch and 3.5-inch HS drive models:
  • 1x x3650 M5 Rear 2x 2.5" HDD Kit (PN 00FK658)
4x 2.5-in. SAS/SATA
hot-swap (rear)

2x M1215
(2+2 drives)

Factory installed:
  • 2x x3650 M5 Rear 2x 2.5" HDD Kit (Independent RAID) (FC A5GH)
Field upgrade for 2.5-inch HS drive models:
  • 2x x3650 M5 Rear 2x 2.5" HDD Kit (PN 00FK658)
2x 3.5-in. SAS/SATA
hot-swap (rear)
(Cascaded)
1x RAID or HBA
(12+2 drives)***
Factory installed:
  • 1x x3650 M5 Rear 2x 3.5" HDD Kit (Cascaded) (FC A5GL)
Field upgrade for 3.5-inch HS drive models:
  • 1x x3650 M5 Rear 2x 3.5" HDD Kit (PN 00FK659)
2x 3.5-in. SAS/SATA
hot-swap (rear)
(Independent RAID)

1x M1215
(2 drives)

Factory installed:
  • 1x x3650 M5 Rear 2x 3.5" HDD Kit (Independent RAID) (FC A5GK)
Field upgrade for 3.5-inch HS drive models:
  • 1x x3650 M5 Rear 2x 3.5" HDD Kit (PN 00FK659)

* RAID or HBA indicates that any combination of the M1215, M5210, and N2215 storage controllers is supported up to a maximum quantity listed; the numbers in brackets (x+y+z) specify the quantity of drives connected to each of the controllers.
# Each PCIe SSD Extender Adapter (PN 00ML997) provides connectivity for up to two PCIe SSDs, and each adapter occupies a PCIe slot. For factory configured models, two or four PCIe SSD Extender Adapters (FC AS95) must be included in the configuration. For field upgrades, the PCIe SSD Upgrade Kit (PN 00FK677) includes two PCIe SSD Extenders.
** Requires the selection of 8x or 16x 2.5-in. hot-swap drive bays (with 16x 2.5-in. drive bays, the internal optical drive cannot be used).
## Requires the selection of 8x 2.5-in. hot-swap drive bays.
*** Two drives in the 2x 3.5-inch Rear HDD Kit are connected to the SAS expander on the 12-drive backplane, that is, to the same storage controller as 12 drives on the front.

Configuration notes:

  • 24x 2.5-inch front drives are supported on storage dense models only (models without the Standard [feature code ATE5] or Advanced [feature code ATE6] OP Panel).
  • 2x 2.5-inch rear drives (1x Rear 2x 2.5" HDD Kit) are supported on 2.5-inch and 3.5-inch drive bay models.
    • The Rear 2.5" HDD Kit is installed in place of the PCIe Riser Card 1, and PCIe slots 1, 2 and 3 are not present. The kit includes special riser that provides PCIe 3.0 x8 slot for the M1215 RAID controller that is dedicated to 2x 2.5-inch rear drives.
  • 4x 2.5-inch rear drives (2x Rear 2x 2.5" HDD Kits) are supported on 2.5-inch hot-swap drive bay models only.
    • The first Rear 2.5" HDD Kit is installed in place of the PCIe Riser Card 1, and PCIe slots 1, 2 and 3 are not present.
    • The second Rear 2.5" HDD Kit is installed in place of the PCIe Riser Card 2, and PCIe slots 6, 7 and 8 are not present.
    • Each kit includes special riser that provides PCIe 3.0 x8 slot for the M1215 RAID controller that is dedicated to 2x 2.5-inch rear drives.
  • 2x 3.5-inch rear drives are supported on 3.5-inch hot-swap drive bay models only.
    • With 8x 3.5-inch HS drive bay models, the 2x 3.5-inch Rear HDD Kit is connected to a dedicated M1215 controller (Independent RAID).
    • With 12x 3.5-inch HS drive bay models, the 2x 3.5-inch Rear HDD Kit can be connected to a dedicated M1215 controller (Independent RAID) or SAS expander on the 12-drive backplane (Cascaded).
    • The Rear 3.5" HDD Kit is installed in place of PCIe Riser Card 2; PCIe slots 6, 7, and 8 are not present.
  • For 8x 3.5-inch and 12x 3.5-inch drive bay models, either 1x Rear 2x 3.5" HDD Kit (Independent RAID) or 1x Rear 2x 2.5" HDD Kit (Independent RAID) can be used in the configuration, but not both.
  • For 12x 3.5-inch drive bay models, either 1x Rear 2x 3.5" HDD Kit (Independent RAID) or 1x Rear 2x 3.5" HDD Kit (Cascaded) can be used in the configuration, but not both. If the Cascaded Kit is used, 1x Rear 2x 2.5" HDD Kit (Independent RAID) also can be used in the configuration.
  • NVMe PCIe SSDs are supported on 8x or 16x 2.5-inch SAS/SATA hot-swap drive bay models only.
    • With one processor, up to one NVMe PCIe SDD Upgrade Kit is supported, and it requires one of the Riser 1 card options with PCIe x8 slots:
      • For the Riser 1 options with 3x PCIe x8 slots (part numbers 00KA519 or 00KA498), the PCIe SSD extenders are supported in PCIe slots 1 and 2.
      • For the Riser 1 options with 1x PCIe x8 slot (part number 00KA489), the PCIe SSD extenders are supported in PCIe slots 3 and 4.
    • With two processors, up to two NVMe PCIe SDD Upgrade Kits are supported, and they require a combination of the Riser 1 and Riser 2 card options with PCIe x8 slots:
      • For the Riser 1 and Riser 2 options with 3x PCIe x8 slots (part numbers 00KA519 [Riser 1] or 00KA498 [Riser 1 or Riser 2]), the PCIe SSD extenders are supported in PCIe slots 1 and 2 (Riser 1), and 6 and 7 (Riser 2).
      • For the Riser 1 and Riser 2 options with 1x PCIe x8 slot (part number 00KA489), the PCIe SSD extenders are supported in PCIe slots 3, 4, 5, and 8.
    • For 16x 2.5-inch SAS/SATA hot-swap drive bay configurations, the internal optical drive is not supported in the configurations with NVMe PCIe SSDs.
    • If only one NVMe PCIe SSD Upgrade Kit is used in the configurations with two processors, up to one 2.5-inch Rear HDD Kit is supported. In other configurations with the NVMe PCIe SSD Upgrade Kits, the 2.5-inch Rear HDD Kit cannot be used.

Controllers for internal storage

The following table lists the storage controllers and options used for internal storage of the System x3650 M5.

Note: SAS RAID controllers and HBAs are supported in low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.

Table 12. RAID controllers and HBAs for internal storage

DescriptionPart numberFeature codeMaximum supportedI/O slots supported
12 Gb SAS/SATA controllers
ServeRAID M5210 SAS/SATA Controller46C9110A3YZ39, 4, 1, 6
ServeRAID M1215 SAS/SATA Controller46C9114A45W39, 4, 1, 6, 3, 8
N2215 SAS/SATA HBA47C8675A3YY39, 4, 1, 6, 2, 7, 5
Hardware upgrades for the M5210 (one per controller)
ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade47C8656A3Z03-
ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade47C8660A3Z13-
ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade47C8664A3Z23-
ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade47C8668A3Z33-
Features on Demand upgrades for the M5210 (system-wide)*
ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade (FOD)47C8708A3Z61-
ServeRAID M5200 Series RAID 6 Upgrade (FOD)47C8706A3Z51**-
ServeRAID M5200 Series Performance Accelerator (FOD)47C8710A3Z71**-
ServeRAID M5200 Series SSD Caching Enabler (FOD)47C8712A3Z81**-
Features on Demand upgrades for the M1215 (system-wide)*
ServeRAID M1200 Zero Cache/RAID 5 Upgrade (FOD)00AE930A5H51-
PCIe extenders (for NVMe PCIe SSDs)
System x NVMe PCIe SSD Extender Adapter00ML997AS9541, 2, 3, 4, 5, 6, 7, 8

* One FoD upgrade enables the feature on all ServeRAID adapters of the same family (M5200 or M1200) installed in the server.
** Requires cache memory upgrade (47C8656, 47C8660, 47C8664, or 47C8668).

The following table summarizes features of supported storage controllers.

Table 13. Storage controller features and specifications summary

FeatureM1215M5210N2215
Part number46C911446C911047C8675
Form factorPCIe low profilePCIe low profilePCIe low profile
Controller chipLSI SAS3008LSI SAS3108LSI SAS3008
Host interfacePCIe 3.0 x8PCIe 3.0 x8PCIe 3.0 x8
Port interface12 Gbps SAS12 Gbps SAS12 Gbps SAS
Number of ports888
Port connectors2x Mini-SAS HD x4
(SFF-8643)
2x Mini-SAS HD x4
(SFF-8643)
2x Mini-SAS HD x4
(SFF-8643)
Drive interfaceSAS, SATASAS, SATASAS, SATA
Drive typeHDD, SSD, SEDHDD, SSD, SEDHDD, SSD
Drive form factorSFF, LFFSFF, LFFSFF, LFF
Hot-swap drivesYesYesYes
Max devices32 (RAID); 64 (JBOD)2401024
RAID levels0/1/10;
Optional 5/50 (00AE930)
0/1/10; Optional 5/50
(RAID 5 FoD, 47C8708,
or cache upgrades);
Optional 6/60 (47C8706)
None
JBOD modeYesYes (without cache)Yes
CacheNone
1 GB no backup (47C8656)
1 GB flash backup (47C8660)
2 GB flash backup (47C8664)
4 GB flash backup (47C8668)

None

SED support (SafeStore)Yes (with RAID 5
FoD upgrade)
Yes (with RAID 5 FoD upgrade
or any cache upgrade)
No
Performance Accelerator (FastPath)NoOptional (47C8710)No
SSD Caching (CacheCade Pro 2.0)NoOptional (47C8712)No

The following table lists supported combinations of the storage controllers and drive types for the System x3650 M5 drive bay configurations.

Table 14. Storage controllers, drive types, and internal drive bays

Drive bay configurationStorage
Controller
Drive type
SAS
HDD
NL SAS
HDD
NL SATA
HDD
SAS
SED
SAS
SSD
SATA
SSD
PCIe
SSD
Front drive bays
8/16/24x 2.5-inch SAS/SATA
hot-swap (front)
M1215YesYesYesYes*YesYesNo
M5210YesYesYesYes**YesYesNo
N2215YesYesYesNoYesYesNo
8/12x 3.5-inch SAS/SATA
hot-swap (front)
M1215YesYesYesNoNoYesNo
M5210YesYesYesNoNoYesNo
N2215YesYesYesNoNoYesNo
4/8x 2.5-inch NVMe PCIe
hot-swap (front)
PCIe SSD
Extender
NoNoNoNoNoNoYes
Rear drive bays
2/4x 2.5-inch SAS/SATA
hot-swap (rear; independent RAID)
M1215YesYesYesYes*YesYesNo
2x 3.5-inch SAS/SATA
hot-swap (rear; cascaded RAID)#
M1215YesYesYesNoNoYesNo
M5210YesYesYesNoNoYesNo
N2215YesYesYesNoNoYesNo
2x 3.5-inch SAS/SATA
hot-swap (rear; independent RAID)
M1215YesYesYesNoNoYesNo

# 3.5" rear drives support cascaded connections only to the SAS expander on the 12-drive backplane (12x 3.5" drive bay models).
* SEDs are supported with the RAID 5 FoD upgrade (00AE930).
** SEDs are supported with the RAID 5 FoD upgrade (47C8708) or any cache upgrade (47C8656, 47C8660, 47C8664, 47C8668).

Drives for internal storage

The following tables list drive options for the System x3650 M5.

Table 15. Drive options for internal storage: 2.5-inch hot-swap drives

DescriptionPart numberFeature codeMaximum supported
2.5-inch hot-swap HDDs - 12 Gbps SAS
300GB 10K 12Gbps SAS 2.5" G3HS HDD00WG685AT8928
300GB 15K 12Gbps SAS 2.5" G3HS HDD00WG660AT8428
600GB 10K 12Gbps SAS 2.5" G3HS HDD00WG690AT8A28
600GB 15K 12Gbps SAS 2.5" G3HS HDD00WG665AT8528
900GB 10K 12Gbps SAS 2.5" G3HS HDD00WG695AT8B28
900GB 15K 12Gbps SAS 2.5" G3HS 512e HDD01GV035AVKU28*
1.2TB 10K 12Gbps SAS 2.5" G3HS HDD00WG700AT8C28
1.8TB 10K 12Gbps SAS 2.5" G3HS 512e HDD00NA271ASBM28
2.4TB 10K 12Gbps SAS 2.5" G3HS 512e HDD01GV070B0YT28*
2.5-inch hot-swap HDDs - 12 Gbps NL SAS
1TB 7.2K 12Gbps NL SAS 2.5'' G3HS HDD00NA491AT7Z28
2TB 7.2K 12Gbps NL SAS 2.5'' G3HS HDD00NA496AT8028
2.5-inch hot-swap HDDs - 6 Gbps NL SATA
500GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD00AJ136A4TW28
1TB 7.2K 6Gbps NL SATA 2.5" G3HS HDD00AJ141A4TX28
2TB 7.2K 6Gbps NL SATA 2.5'' G3HS 512e HDD00NA526AT8128
2.5-inch hot-swap SEDs - 12 Gbps SAS
300GB 10K 12Gbps SAS 2.5" G3HS SED00WG705AT8D28
600GB 10K 12Gbps SAS 2.5" G3HS SED00WG710AT8E28
900GB 10K 12Gbps SAS 2.5" G3HS SED00WG715AT8F28
1.2TB 10K 12Gbps SAS 2.5" G3HS SED00WG720AT8G28
2.4TB 10K 12Gbps SAS 2.5" G3HS 512e FIPS 140-2 SED01GV080B0YW28*
2.5-inch hot-swap SEDs - 12 Gbps NL SAS
2TB 7.2K 12Gbps NL SAS 2.5'' G3HS 512e FIPS 140-2 SED01GR670AUCF28*
2.5-inch hot-swap SSDs - Enterprise Performance 12 Gbps SAS (SS300)
400GB Enterprise Performance 12G SAS G3HS 2.5" SSD01GV711AVL028*
800GB Enterprise Performance 12G SAS G3HS 2.5" SSD01GV716AVL128*
1.6TB Enterprise Performance 12G SAS G3HS 2.5" SSD01GV721AVL228*
2.5-inch hot-swap SSDs - Enterprise 12 Gbps SAS
200GB 12G SAS 2.5" MLC G3HS Enterprise SSD00FN379AS7C28
400GB 12G SAS 2.5" MLC G3HS Enterprise SSD00FN389AS7E28
800GB 12G SAS 2.5" MLC G3HS Enterprise SSD00FN399AS7G28
1.6TB 12G SAS 2.5" MLC G3HS Enterprise SSD00FN409AS7J28
2.5-inch hot-swap SSDs - Enterprise Mainstream 12 Gbps SAS
400GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD00YC460AT9M28
800GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD00YC465AT9N28
1.6TB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD00YC470AT9P28
2.5-inch hot-swap SSDs - PM1635a Enterprise Mainstream 12 Gbps SAS
PM1635a 400GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD01GV761AWEY28*
PM1635a 800GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD01GV766AWEZ28*
PM1635a 1.6TB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD01GV771AWF028*
2.5-inch hot-swap SSDs - Enterprise Capacity 12 Gbps SAS
PM1633a 3.84TB Enterprise Capacity 12Gb SAS G3HS 2.5" SSD01GR786AVKV28*
PM1633a 7.68TB Enterprise Capacity 12Gb SAS G3HS 2.5" SSD01GR771AUEJ28*
2.5-inch hot-swap SSDs - Enterprise Performance 6 Gbps SATA
Intel S3710 800GB Enterprise Performance SATA G3HS 2.5" SSD00YC330AT9E28
2.5-inch hot-swap SSDs - Enterprise Performance PCIe 3.0 x4**
Intel P3700 400GB NVMe 2.5" G3HS Enterprise Performance PCIe SSD00YA818AT7V8
Intel P3700 800GB NVMe 2.5" G3HS Enterprise Performance PCIe SSD00YA821AT7W8
Intel P3700 1.6TB NVMe 2.5" G3HS Enterprise Performance PCIe SSD00YA824AT7X8
Intel P3700 2.0TB NVMe 2.5" G3HS Enterprise Performance PCIe SSD00YA827AT7Y8
2.5-inch hot-swap SSDs - 5100 Enterprise Mainstream 6 Gbps SATA
5100 240GB Enterprise Mainstream SATA G3HS 2.5" SSD01GV843AXFV28*
5100 480GB Enterprise Mainstream SATA G3HS 2.5" SSD01GV848AXFW28*
5100 960GB Enterprise Mainstream SATA G3HS 2.5" SSD01GV853AXFX28*
5100 1.92TB Enterprise Mainstream SATA G3HS 2.5" SSD01GV858AXFY28*
5100 3.84TB Enterprise Mainstream SATA G3HS 2.5" SSD01GV863AXFZ28*
2.5-inch hot-swap SSDs - S3610 Enterprise Mainstream 6 Gbps SATA
Intel S3610 480GB Enterprise Mainstream SATA G3HS 2.5" SSD00YK212AU3C28
Intel S3610 800GB Enterprise Mainstream SATA G3HS 2.5" SSD00YK217AU3D28
Intel S3610 1.2TB Enterprise Mainstream SATA G3HS 2.5" SSD00YK222AU3E28
2.5-inch hot-swap SSDs - S4600 Enterprise Mainstream 6 Gbps SATA
Intel S4600 240GB Enterprise Mainstream SATA G3HS 2.5" SSD4XB7A08499B10A28*
Intel S4600 480GB Enterprise Mainstream SATA G3HS 2.5" SSD7SD7A05713B10B28*
Intel S4600 960GB Enterprise Mainstream SATA G3HS 2.5" SSD7SD7A05712B10C28*
Intel S4600 1.92TB Enterprise Mainstream SATA G3HS 2.5" SSD7SD7A05711B10D28*
2.5-inch hot-swap SSDs - Enterprise Mainstream PCIe 3.0 x4**
960GB NVMe 2.5" Enterprise Mainstream PCIe SSD00YK284AVP18*
1.92TB NVMe 2.5" Enterprise Mainstream PCIe SSD00YK285AVP28*
2.5-inch hot-swap SSDs - PM963 Enterprise Mainstream PCIe 3.0 x4**
PM963 1.92TB NVMe 2.5" Enterprise Value PCIe SSD01GR660AVPN8*
PM963 3.84TB NVMe 2.5" Enterprise Value PCIe SSD01GT715AVPP8*
2.5-inch hot-swap SSDs - M500DC Enterprise Mainstream 6 Gbps SATA
M500DC 480GB Enterprise Mainstream Plus SATA G3HS 2.5" SSD00YC529ATDW28
2.5-inch hot-swap SSDs - 5100 Enterprise Entry 6 Gbps SATA
5100 480GB Enterprise Entry SATA G3HS 2.5" SSD01KR496AXGL28*
5100 960GB Enterprise Entry SATA G3HS 2.5" SSD01KR501AXGM28*
5100 1.92TB Enterprise Entry SATA G3HS 2.5" SSD01KR506AXGN28*
5100 3.84TB Enterprise Entry SATA G3HS 2.5" SSD01KR511AXGP28*
2.5-inch hot-swap SSDs - Enterprise Entry 6 Gbps SATA
1.92TB Enterprise Entry SATA G3HS 2.5" SSD01GR711AUE728
2.5-inch hot-swap SSDs - S3520 Enterprise Entry 6 Gbps SATA
Intel S3520 240GB Enterprise Entry SATA G3HS 2.5" SSD01GR726AUEM28
Intel S3520 480GB Enterprise Entry SATA G3HS 2.5" SSD01GR731AUEP28
Intel S3520 800GB Enterprise Entry SATA G3HS 2.5" SSD01KR466AXGB28
Intel S3520 960GB Enterprise Entry SATA G3HS 2.5" SSD01GR736AUER28
Intel S3520 1.2TB Enterprise Entry SATA G3HS 2.5" SSD01GR802AXGD28
Intel S3520 1.6TB Enterprise Entry SATA G3HS 2.5" SSD01GR817AXGF28
2.5-inch hot-swap SSDs - S4500 Enterprise Entry 6 Gbps SATA
Intel S4500 240GB Enterprise Entry SATA G3HS 2.5" SSD7SD7A05732B0Z828*
Intel S4500 480GB Enterprise Entry SATA G3HS 2.5" SSD7SD7A05731B0Z928*
Intel S4500 960GB Enterprise Entry SATA G3HS 2.5" SSD7SD7A05730B0ZA28*
Intel S4500 1.92TB Enterprise Entry SATA G3HS 2.5" SSD4XB7A08493B0ZB28*
Intel S4500 3.84TB Enterprise Entry SATA G3HS 2.5" SSD4XB7A08494B0ZC28*
2.5-inch hot-swap SSDs - PM863a Enterprise Entry 6 Gbps SATA
PM863a 240GB Enterprise Entry SATA G3HS 2.5" SSD01GR836AVHP28
PM863a 480GB Enterprise Entry SATA G3HS 2.5" SSD01GR841AVHQ28
PM863a 960GB Enterprise Entry SATA G3HS 2.5" SSD01GR846AVHR28
2.5-inch hot-swap SSDs - Enterprise Value 6 Gbps SATA
120GB SATA 2.5" MLC G3HS Enterprise Value SSD00AJ395A57728
240GB SATA 2.5" MLC G3HS Enterprise Value SSD00AJ400A57828
480GB SATA 2.5" MLC G3HS Enterprise Value SSD00AJ405A57928
800GB SATA 2.5" MLC G3HS Enterprise Value SSD00AJ410A57A28
2.5-inch hot-swap SSDs - Enterprise Value PCIe 3.0 x4**
Intel P3600 400GB NVMe 2.5" G3HS Enterprise Value PCIe SSD90Y3227A5RW8
Intel P3600 800GB NVMe 2.5" G3HS Enterprise Value PCIe SSD90Y3230A5RX8
Intel P3600 1.6TB NVMe 2.5" G3HS Enterprise Value PCIe SSD90Y3233A5RY8
Intel P3600 2.0TB NVMe 2.5" G3HS Enterprise Value PCIe SSD90Y3236A5RZ8
2.5-inch hot-swap SED SSDs - Enterprise Performance 12 Gbps SAS (SS300)
400GB Enterprise Performance 12Gbps SAS G3HS 2.5" SSD FIPS7SD7A05748AXG528*
800GB Enterprise Performance 12Gbps SAS G3HS 2.5" SSD FIPS7SD7A05747AXG628*
1.6TB Enterprise Performance 12Gbps SAS G3HS 2.5" SSD FIPS7SD7A05746AXG728*
2.5-inch hot-swap SED SSDs - Enterprise 12 Gbps SAS
HGST SSC+ 400GB 12Gb SAS FIPS SED 2.5" Enterprise G3HS SSD01GR600AUCC28*
HGST SSC+ 800GB 12Gb SAS FIPS SED 2.5" Enterprise G3HS SSD01GR605AUCD28*
HGST SSC+ 1.6TB 12Gb SAS FIPS SED 2.5" Enterprise G3HS SSD01GR610AUCE28*

* Not supported with the Intel Xeon processor E5-2600 v3 product family.
** NVMe PCIe SSDs support informed hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap. 

Table 16. Drive options for internal storage: 3.5-inch hot-swap drives

DescriptionPart numberFeature codeMaximum supported
3.5-inch hot-swap HDDs - 12 Gbps SAS
300GB 15K 12Gbps SAS 3.5" G2HS HDD (2.5" HDD with 3.5" tray)00WG675AT8714
600GB 15K 12Gbps SAS 3.5" G2HS HDD (2.5" HDD with 3.5" tray)00WG680AT8814
900GB 15K 12Gbps SAS 3.5" G2HS 512e HDD (2.5" HDD with 3.5" tray)01GV040AVL914*
3.5-inch hot-swap HDDs - 12 Gbps NL SAS
1TB 7.2K 12Gbps NL SAS 3.5" G2HS HDD00YL702ATYM14
2TB 7.2K 12Gbps NL SAS 3.5" G2HS HDD00YK000ATYL14
2TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD00FN188A5VP14
4TB 7.2K 12Gbps NL SAS 3.5" G2HS HDD00YK005ATYN14
6TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD00FN228A5VR14
8TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD00WH121ATRS14
10TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD00YK336AU7R14
12TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD01GV055B11914*
3.5-inch hot-swap HDDs - 6 Gbps NL SAS
2TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD90Y8572A2U014
3.5-inch hot-swap HDDs - 6 Gbps NL SATA
500GB 7.2K 6Gbps NL SATA 3.5" G2HS HDD81Y9786A22Y14
1TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD81Y9790A22P14
2TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD81Y9794A22T14
4TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD49Y6002A3W914
4TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD00FN143A5VH14
6TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD00FN173A5VM14
8TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD00WH126ATRT14
10TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD00YK341AU7S14
12TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD01GV060B11A14*
3.5-inch hot-swap SEDs - 12 Gbps NL SAS
2TB 7.2K 12Gbps NL SAS 3.5'' G2HS 512e FIPS 140-2 SED01GR676AUCM14*
4TB 7.2K 12Gbps NL SAS 3.5'' G2HS FIPS 140-2 SED01GR682AUCN14*
6TB 7.2K 12Gbps NL SAS 3.5'' G2HS 512e FIPS 140-2 SED01GR688AUCP14*
8TB 7.2K 12Gbps NL SAS 3.5'' G2HS 512e FIPS 140-2 SED01GR694AUCQ14*
3.5-inch hot-swap SSDs - Enterprise Performance 12 Gbps SAS (SS300)
400GB Enterprise Performance 12G SAS HS 3.5" SSD01GV726AVL314*
800GB Enterprise Performance 12G SAS HS 3.5" SSD01GV731AVL414*
1.6TB Enterprise Performance 12G SAS HS 3.5" SSD01GV736AVL514*
3.5-inch hot-swap SSDs - Enterprise 12 Gbps SAS
1.6TB 12Gb SAS 3.5" MLC HS Enterprise SSD01GR881AUBU14
3.5-inch hot-swap SSDs - Enterprise Capacity 12 Gbps SAS
PM1633a 3.84TB Enterprise Capacity 12Gb SAS HS 3.5" SSD01GR791AVKW14*
3.5-inch hot-swap SSDs - Enterprise Capacity 6 Gbps SAS
3.84TB 6Gb SAS 3.5" Enterprise Capacity HS MLC SSD01GR871AUBS14
3.5-inch hot-swap SSDs - Enterprise Performance 6 Gbps SATA
Intel S3710 800GB Enterprise Performance SATA HS 3.5" SSD00YC345AT9H14
3.5-inch hot-swap SSDs - 5100 Enterprise Mainstream 6 Gbps SATA
5100 240GB Enterprise Mainstream SATA HS 3.5" SSD01GV868AXG014*
5100 480GB Enterprise Mainstream SATA HS 3.5" SSD01GV873AXG114*
5100 960GB Enterprise Mainstream SATA HS 3.5" SSD01GV878AXG214*
5100 1.92TB Enterprise Mainstream SATA HS 3.5" SSD01GV883AXG314*
5100 3.84TB Enterprise Mainstream SATA HS 3.5" SSD01GV090AXG414*
3.5-inch hot-swap SSDs - S3610 Enterprise Mainstream 6 Gbps SATA
Intel S3610 480GB Enterprise Mainstream SATA HS 3.5" SSD00YK237AU3H14
Intel S3610 800GB Enterprise Mainstream SATA HS 3.5" SSD00YK242AU3J14
Intel S3610 1.2TB Enterprise Mainstream SATA HS 3.5" SSD00YK247AU3K14
3.5-inch hot-swap SSDs (2.5" SSD in 3.5" drive tray) - S4600 Enterprise Mainstream 6 Gbps SATA
Intel S4600 240GB Enterprise Mainstream SATA HS 3.5" SSD4XB7A08500B10E14*
Intel S4600 480GB Enterprise Mainstream SATA HS 3.5" SSD7SD7A05710B10F14*
Intel S4600 960GB Enterprise Mainstream SATA HS 3.5" SSD7SD7A05709B10G14*
Intel S4600 1.92TB Enterprise Mainstream SATA HS 3.5" SSD7SD7A05708B10H14*
3.5-inch hot-swap SSDs - 5100 Enterprise Entry 6 Gbps SATA
5100 480GB Enterprise Entry SATA HS 3.5" SSD01KR516AXGQ14*
5100 960GB Enterprise Entry SATA HS 3.5" SSD01KR521AXGR14*
5100 1.92TB Enterprise Entry SATA HS 3.5" SSD01KR526AXGS14*
5100 3.84TB Enterprise Entry SATA HS 3.5" SSD01KR531AXGT14*
3.5-inch hot-swap SSDs - PM863a Enterprise Entry 6 Gbps SATA
PM863a 240GB Enterprise Entry SATA HS 3.5" SSD01GR899AVHS14
PM863a 480GB Enterprise Entry SATA HS 3.5" SSD01GR851AVHT14
PM863a 960GB Enterprise Entry SATA HS 3.5" SSD01GR856AVHU14
3.5-inch hot-swap SSDs - S3520 Enterprise Entry 6 Gbps SATA
Intel S3520 240GB Enterprise Entry SATA HS 3.5" SSD01GR741AUF014
Intel S3520 480GB Enterprise Entry SATA HS 3.5" SSD01GR746AUF114
Intel S3520 800GB Enterprise Entry SATA HS 3.5" SSD01KR471AXGC14
Intel S3520 960GB Enterprise Entry SATA HS 3.5" SSD01GR751AUF214
Intel S3520 1.2TB Enterprise Entry SATA HS 3.5" SSD01GR807AXGE14
Intel S3520 1.6TB Enterprise Entry SATA HS 3.5" SSD01GR822AXGG14
3.5-inch hot-swap SSDs (2.5" SSD in 3.5" drive tray) - S4500 Enterprise Entry 6 Gbps SATA
Intel S4500 240GB Enterprise Entry SATA HS 3.5" SSD7SD7A05729B0ZD14*
Intel S4500 480GB Enterprise Entry SATA HS 3.5" SSD7SD7A05728B0ZE14*
Intel S4500 960GB Enterprise Entry SATA HS 3.5" SSD7SD7A05727B0ZF14*
Intel S4500 1.92TB Enterprise Entry SATA HS 3.5" SSD4XB7A08495B0ZG14*
Intel S4500 3.84TB Enterprise Entry SATA HS 3.5" SSD4XB7A08496B0ZH14*
3.5-inch hot-swap SSDs - Enterprise Entry 6 Gbps SATA
1.92TB Enterprise Entry SATA HS 3.5" SSD01GR721AUE914
3.5-inch hot-swap SSDs - Enterprise Value 6 Gbps SATA
120GB SATA 3.5" MLC HS Enterprise Value SSD00AJ435A57F14
480GB SATA 3.5" MLC HS Enterprise Value SSD00AJ445A57H14
3.5-inch hot-swap SED SSDs - Enterprise Performance 12 Gbps SAS (SS300)
400GB Enterprise Performance 12Gb SAS HS 3.5" SSD FIPS7SD7A05745AXG814*
800GB Enterprise Performance 12Gb SAS HS 3.5" SSD FIPS7SD7A05744AXG914*
1.6TB Enterprise Performance 12Gb SAS HS 3.5" SSD FIPS7SD7A05743AXGA14*

* Not supported with the Intel Xeon processor E5-2600 v3 product family.

Optical drives

The System x3650 M5 server supports the optical drive options listed in the following table. Storage dense models with 12x 3.5-inch or up to 24x 2.5-inch drive bays on the front do not support internal optical drive; a supported external optical drive can be used instead.

Table 17. Optical drives

DescriptionPart numberFeature codeMaximum supported
Optical drives
Ultraslim 9.5mm SATA DVD-ROM00AM066A5KG1
Ultraslim 9.5mm SATA Multi Burner00AM067A5KH1
Optical drive cable (Required)
System x3650 M5 ODD Cable Kit00AL956None*1

* The ODD Cable Kit part number (00AL956) includes two cables: ODD Cable for 3.5" Model (feature code A5GM) and ODD Cable for 2.5" Model (feature code A5V7).

Ultraslim 9.5mm SATA DVD-ROM (part number 00AM066) supports the following media and speeds for reading:

  • CD-ROM/CD-DA (DAE) 24X
  • CD-R/RW 24X
  • DVD-ROM 8X
  • DVD-R 8X
  • DVD+R 8X
  • DVD-R DL 6X
  • DVD+R DL 8X
  • DVD-RW 8X
  • DVD+RW 8X
  • DVD-RAM (4.7 GB) 5X

Ultraslim 9.5mm SATA Multi Burner (part number 00AM067) supports the same media and speeds for reading as DVD-ROM (part number 00AM066), and it supports the following media and speeds for writing:

  • CD-R 24X
  • CD-RW 4X, High Speed CD-RW 10X, Ultra Speed CD-RW 24X
  • DVD-R 8X
  • DVD+R 8X
  • DVD-R DL 6X
  • DVD+R DL 6X
  • DVD-RW 6X
  • DVD+RW 8X
  • DVD-RAM 5X

I/O expansion

The System x3650 M5 server supports up to nine PCIe slots: one slot on the system planar that is dedicated for an internal storage controller, two regular PCIe slots on the system planar, and up to six PCIe slots with different riser cards installed into two riser sockets on the system planar (one riser socket supports installation of one riser card). The slot form factors are as follows:

  • Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, full-length (PCIe x16 slot is double-wide)
  • Slot 2: PCIe 3.0 x8; full-height, full-length (not present if the slot 1 is PCIe x16)
  • Slot 3: PCIe 3.0 x8 or ML2; full-height, half-length
  • Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar)
  • Slot 5: PCIe 3.0 x8; low profile (vertical slot on system planar)
  • Slot 6: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, full-length (PCIe x16 slot is double-wide)
  • Slot 7: PCIe 3.0 x8; full-height, full-length (not present if the slot 6 is PCIe x16)
  • Slot 8: PCIe 3.0 x8; full-height, half-length
  • Slot 9: PCIe 3.0 x8 (dedicated for an internal RAID controller)

Notes:

  • Slots 5, 6, 7, and 8 require the second processor to be installed.
  • For customers who need three PCIe 3.0 x16 slots in the System x3650 M5 for their specific workloads, a special base model 8871-AC3 that can be configured with 3x PCIe 3.0 x16 slots (onboard slot 5 + slots 1 and 6 on the riser cards) is available via CTO (x-config only).

The locations of the PCIe slots are shown in the following figure.

 

Figure 14. Slot locations

Riser 1 supplies slots 1, 2, and 3, and Riser 2 supplies slots 6, 7, and 8. The slots that are available for use depend on the number of riser cards that are installed and whether the second processor is installed, as shown in the following table.

Notes:

  • PCIe x8 riser card part numbers are 00KA519 (Riser Card 1) and 00KA498 (Riser Card 1 or 2).
  • PCIe x16 riser card part numbers are 00KA504 (Riser Card 1) and 00KA489 (Riser Card 1 or 2).

Table 18. Slots available for use

Riser Card 1Riser Card 2Slots available for use
One processor
NoneNone4, 9
PCIe x8None1, 2, 3, 4, 9
PCIe x16None1, 3, 4, 9
Two processors
NoneNone4, 5, 9
PCIe x8None1, 2, 3, 4, 5, 9
PCIe x8PCIe x81, 2, 3, 4, 5, 6, 7, 8, 9
PCIe x8PCIe x161, 2, 3, 4, 5, 6, 8, 9
PCIe x16None1, 3, 4, 5, 9
PCIe x16PCIe x81, 3, 4, 5, 6, 7, 8, 9
PCIe x16PCIe x161, 3, 4, 5, 6, 8, 9

Standard models do not include any riser cards. The following table lists available PCIe riser card options.

Table 19. PCIe riser cards and miscellaneous options

DescriptionPart numberFeature codeMaximum supported
Riser 1 options (PCIe x8 riser supplies slots 1, 2 and 3; PCIe x16 riser supplies slots 1 and 3)
System x3650 M5 PCIe Riser 1 (1 x16 FH/FL + 1 x8 ML2 Slots)00KA504A5FR1
System x3650 M5 PCIe Riser 1 (2 x8 FH/FL + 1 x8 ML2 Slots)00KA519A5FQ1
System x3650 M5 PCIe Riser (1 x16 FH/FL + 1 x8 FH/HL Slots)00KA489A5FN1
System x3650 M5 PCIe Riser (2 x8 FH/FL + 1 x8 FH/HL Slots)00KA498A5FP1
Riser 2 options (PCIe x8 riser supplies slots 6, 7 and 8; PCIe x16 riser supplies slots 6 and 8)
System x3650 M5 PCIe Riser (1 x16 FH/FL + 1 x8 FH/HL Slots)00KA489A5R51
System x3650 M5 PCIe Riser (2 x8 FH/FL + 1 x8 FH/HL Slots)00KA498A5R61
Serial port bracket
COM Port Bracket00KA161A5AN1

Riser option part numbers 00KA489 and 00KA498 can be installed in both riser slots 1 and 2; for CTO or special bid orders these option part numbers have different feature codes depending on the riser slot into which they are installed.

The COM Port Bracket, part number 00KA161, is used for mounting the external serial port on the rear of the System x3650 M5. This option includes the bracket and the cable. The COM Port option is mounted in place of the PCIe slot 5, and the PCIe slot 5 cannot be used.

Network adapters

The System x3650 M5 supports four integrated Gigabit Ethernet ports. Optionally, the server supports ML2 adapters that are installed in the custom ML2 slot provided by the PCIe ML2 riser cards (part numbers 00KA504 and 00KA519). This slot supports adapters with either two 10 Gb ports or four Gigabit Ethernet ports and supports direct connectivity to the IMM2.1 service processor for out-of-band systems management.

The integrated network interface controller (NIC) has the following features:

  • A Broadcom BCM5719 chip
  • Four Gigabit Ethernet ports
  • NIC Teaming (load balancing and failover)
  • Ethernet features:
    • Compliant with 1 Gb Ethernet IEEE 802.3, 802.3u, and 802.3ab PHY specifications
    • Integrated PHY for 10/100/1000 Mbps for multispeed, full, and half-duplex auto-negotiation
    • Automatic MDI crossover
    • IEEE 802.3x-compliant flow control support
    • IEEE 1588 protocol and 802.1AS time synchronization implementation
    • IEEE802.3az - Energy Efficient Ethernet (EEE)
  • I/O Virtualization features:
    • I/O Virtualization support for VMware NetQueue and Microsoft virtual machine queue (VMQ)
    • Function Level Reset (FLR)
    • IEEE 802.1q Virtual Local Area Network (VLAN) tagging support
  • Stateless offload and performance features:
    • TCP, IP, and User Datagram Protocol (UDP) checksum offload
    • TCP segmentation offload (TCO)
    • Large Send Offload (LSO)
    • Receive Side Scaling (RSS) and Transmit Side Scaling (TSS)
    • Message Signal Interrupt (MSI) and Message Signal Interrupt Extension (MSI-X) support
    • Support for jumbo frames up to 9600 bytes

The following table lists additional supported Ethernet network adapters, transceivers, and cables.

Table 20. Ethernet network adapters, transceivers, and cables

DescriptionPart numberFeature codeMaximum supported#I/O slots supported
100 Gb Ethernet / EDR InfiniBand - PCIe
Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adpt.00KH924ASWQ1 / 2*1, 6†
Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adpt.00MM960ATRP1 / 2*1, 6†
Intel Omni-Path - PCIe
Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA00WE023AU0A2 / 2*1, 2, 4, 5, 6, 7
Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA00WE027AU0B1 / 2*1, 6†
40 Gb Ethernet / FDR InfiniBand - ML2
Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter00FP650A5RK1*3
40 Gb Ethernet - PCIe
Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter00MM950ATRN3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
40 Gb Ethernet / FDR InfiniBand - PCIe
Mellanox ConnectX-3 2x40GbE/FDR IB VPI QSFP+ Adapter00D9550A3PN3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
25 Gb Ethernet - ML2
Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter00MN990ATZR1*3
25 Gb Ethernet - PCIe
Mellanox ConnectX-4 Lx 2x25GbE SFP28 Adapter01GR250AUAJ3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
10 Gb Ethernet - ML2
Broadcom NetXtreme II ML2 Dual Port 10GbaseT00D2026A40S13
Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+00D2028A40T1*3
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter00AG560AT7U1*3
Emulex VFA5 ML2 FCoE/iSCSI License (FoD)
(Upgrade for 00AG560 - one per adapter)
00D8544A4NZ1-
Emulex VFA5.2 ML2 2x10GbE SFP+ Adapter & FCoE/iSCSI01CV770AU7Z1*3
Intel X540 ML2 Dual Port 10GbaseT Adapter00D1994A40P13
Intel X710-DA2 ML2 2x10GbE SFP+ Adapter00JY940ATRH1*3
10 Gb Ethernet - PCIe
Broadcom NetXtreme 2x10GbE BaseT Adapter44T1370A5GZ4 / 81, 2, 3, 4, 5, 6, 7, 8
Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter94Y5180A4Z63 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
Emulex VFA5 2x10 GbE SFP+ PCIe Adapter00JY820A5UT3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter00AG570AT7S3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
Emulex VFA5 FCoE/iSCSI SW for PCIe Adapter (FoD)
(Upgrade for 00JY820 and 00AG570 - one per adapter)
00JY824A5UV3 / 6-
Emulex VFA5 2x10 GbE SFP+ Adapter & FCoE/iSCSI SW00JY830A5UU3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
Emulex VFA5.2 2x10 GbE SFP+ Adapter & FCoE/iSCSI SW00AG580AT7T3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
Intel X520 Dual Port 10GbE SFP+ Adapter49Y7960A2EC4 / 8*1, 2, 3, 4, 5, 6, 7, 8
Intel X540-T2 Dual Port 10GBaseT Adapter49Y7970A2ED4 / 81, 2, 3, 4, 5, 6, 7, 8
Intel X550-T1 Single Port 10GBase-T Adapter00MM850ATRY4 / 8§1, 2, 3, 4, 5, 6, 7, 8
Intel X550-T2 Dual Port 10GBase-T Adapter00MM860ATPX4 / 81, 2, 3, 4, 5, 6, 7, 8
Intel X710-DA2 2x10GbE SFP+ Adapter01DA900AU2Y3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
Mellanox ConnectX-3 10 GbE Adapter00D9690A3PM3 / 6*1, 2, 3, 4, 5, 6, 7, 8‡
1 Gb Ethernet - ML2
Intel I350-T4 ML2 Quad Port GbE Adapter00D1998A40R13
1 Gb Ethernet - PCIe
Broadcom NetXtreme 2xGbE BaseT Adapter42C178029954 / 81, 2, 3, 4, 5, 6, 7, 8
Broadcom NetXtreme I Dual Port GbE Adapter90Y9370A2V44 / 81, 2, 3, 4, 5, 6, 7, 8
Broadcom NetXtreme I Quad Port GbE Adapter90Y9352A2V34 / 81, 2, 3, 4, 5, 6, 7, 8
Intel I350-F1 1xGbE Fiber Adapter00AG500A56K4 / 81, 2, 3, 4, 5, 6, 7, 8
Intel I350-T2 2xGbE BaseT Adapter00AG510A56L4 / 81, 2, 3, 4, 5, 6, 7, 8
Intel I350-T4 4xGbE BaseT Adapter00AG520A56M4 / 81, 2, 3, 4, 5, 6, 7, 8

# The maximum quantity shown is with one processor / two processors (this does not apply to ML2 adapters).
† Supported only in the PCIe 3.0 x16 slots supplied by the PCIe x16 riser cards (part numbers 00KA504 and 00KA489).

* The adapter comes without transceivers or cables; for ordering transceivers or cables, see the configuration notes below the table.
‡ Slot 3 is supported only with the PCIe x16 Riser 1 (feature code A5FN). Slot 8 is supported only with the PCIe x16 Riser 2 (feature code A5R5).
§ Not supported with the Intel Xeon processor E5-2600 v3 product family.

Configuration notes:

  • ML2 network adapters are supported in the ML2 slot 1 supplied by one of the ML2 Riser Cards (part numbers 00KA504 and 00KA519).
  • Unless otherwise specified in the table footnote for the specific adapter, PCIe x8 network adapters are supported in the low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
  • PCIe x16 Low Profile network adapters are supported in the full-height PCIe x16 slots supplied by the riser cards 1 and 2.
  • Some adapters require supported transceivers or DAC cables to be purchased for the adapter. The maximum number of transceivers or cables that are supported per adapter equals the quantity of the adapter ports, and all adapter ports must have the same type of the transceiver or cable selected.

The following table lists transceivers and cables for the 10 GbE SFP+ adapters.

Table 21. Transceivers and cables for 10 GbE SFP+ adapters

DescriptionPart numberFeature code
10 GbE SFP+ SR transceivers for 10 GbE SFP+ adapters
Lenovo 10GBASE-SR SFP+ Transceiver46C34475053
Optical cables for 10 GbE SFP+ SR transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable00MN499ASR5
Lenovo 1m LC-LC OM3 MMF Cable00MN502ASR6
Lenovo 3m LC-LC OM3 MMF Cable00MN505ASR7
Lenovo 5m LC-LC OM3 MMF Cable00MN508ASR8
Lenovo 10m LC-LC OM3 MMF Cable00MN511ASR9
Lenovo 15m LC-LC OM3 MMF Cable00MN514ASRA
Lenovo 25m LC-LC OM3 MMF Cable00MN517ASRB
Lenovo 30m LC-LC OM3 MMF Cable00MN520ASRC
Passive SFP+ DAC cables for 10 GbE SFP+ adapters
Lenovo 0.5m Passive SFP+ DAC Cable00D6288A3RG
Lenovo 1m Passive SFP+ DAC Cable90Y9427A1PH
Lenovo 1.5m Passive SFP+ DAC Cable00AY764A51N
Lenovo 2m Passive SFP+ DAC Cable00AY765A51P
Lenovo 3m Passive SFP+ DAC Cable90Y9430A1PJ
Lenovo 5m Passive SFP+ DAC Cable90Y9433A1PK
Lenovo 7m Passive SFP+ DAC Cable00D6151A3RH

The following table lists transceivers and cables for the 25 GbE SFP28 adapters.

Table 22. Transceivers and cables for 25 GbE SFP28 adapters

DescriptionPart numberFeature code
25 GbE SFP28 SR transceivers for 25 GbE SFP+ adapters
Lenovo 25GBase-SR SFP28 Transceiver7G17A03537AV1B
Passive copper cables for 25 GbE SFP28 network adapters
Lenovo 1m Passive 25G SFP28 DAC Cable7Z57A03557AV1W
Lenovo 3m Passive 25G SFP28 DAC Cable7Z57A03558AV1X
Lenovo 5m Passive 25G SFP28 DAC Cable7Z57A03559AV1Y

The following table lists transceivers and cables for the 40 GbE QSFP+ adapters.

Table 23. Transceivers and cables for 40 GbE QSFP+ adapters

DescriptionPart numberFeature code
40 GbE QSFP+ transceivers for 40 GbE network adapters
Lenovo 40GBASE-SR4 QSFP+ Transceiver49Y7884A1DR
Optical cables for 40 GbE QSFP+ SR4 transceivers
Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable00VX003AT2U
Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable00VX005AT2V
Passive copper cables for 40 GbE QSFP+ network adapters
Lenovo 1m Passive QSFP+ DAC Cable49Y7890A1DP
Lenovo 3m Passive QSFP+ DAC Cable49Y7891A1DQ

The following table lists cables for the Mellanox FDR InfiniBand QSFP adapters.

Table 24. Cables for Mellanox FDR InfiniBand QSFP adapters

DescriptionPart numberFeature code
Passive copper cables for Mellanox FDR InfiniBand QSFP adapters
0.75m Mellanox QSFP Passive DAC Cable00KF002ARZB
1m Mellanox QSFP Passive DAC Cable00KF003ARZC
1.25m Mellanox QSFP Passive DAC Cable00KF004ARZD
1.5m Mellanox QSFP Passive DAC Cable00KF005ARZE
3m Mellanox QSFP Passive DAC Cable00KF006ARZF
Active optical cables for Mellanox FDR InfiniBand QSFP adapters
3m Mellanox IB FDR Active Optical Fiber Cable00KF007ARYC
5m Mellanox IB FDR Active Optical Fiber Cable00KF008ARYD
10m Mellanox IB FDR Active Optical Fiber Cable00KF009ARYE
15m Mellanox IB FDR Active Optical Fiber Cable00KF010ARYF
20m Mellanox IB FDR Active Optical Fiber Cable00KF011ARYG
30m Mellanox IB FDR Active Optical Fiber Cable00KF012ARYH

The following table lists transceivers and cables for the 100 GbE QSFP28 network adapters.

Table 25. Transceivers and cables for 100 GbE QSFP28 network adapters

DescriptionPart numberFeature code
100 GbE QSFP28 transceivers for 100 GbE QSFP28 network adapters
Lenovo 100GBase-SR4 QSFP28 Transceiver7G17A03539AV1D
Optical cables for 100 GbE QSFP28 SR4 transceivers
Lenovo 5m MPO-MPO OM4 MMF Cable7Z57A03567AV25
Lenovo 10m MPO-MPO OM4 MMF Cable7Z57A03569AV27
Lenovo 20m MPO-MPO OM4 MMF Cable7Z57A03571AV29
Optical breakout cables for 100 GbE QSFP28 SR4 transceivers
Lenovo 1m MPO-MPO Breakout OM4 MMF Cable7Z57A03573AV2B
Lenovo 3m MPO-MPO Breakout OM4 MMF Cable7Z57A03574AV2C
Lenovo 5m MPO-MPO Breakout OM4 MMF Cable7Z57A03575AV2D
Passive copper cables for 100 GbE QSFP28 network adapters
Lenovo 1m Passive 100G QSFP28 DAC Cable7Z57A03561AV1Z
Lenovo 3m Passive 100G QSFP28 DAC Cable7Z57A03562AV20
Lenovo 5m Passive 100G QSFP28 DAC Cable7Z57A03563AV21
Passive copper breakout cables for 100 GbE QSFP28 network adapters
Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable7Z57A03564AV22
Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable7Z57A03565AV23
Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable7Z57A03566AV24
Active optical cables for 100 GbE QSFP28 network adapters
Lenovo 3m 100G QSFP28 Active Optical Cable7Z57A03546AV1L
Lenovo 5m 100G QSFP28 Active Optical Cable7Z57A03547AV1M
Lenovo 10m 100G QSFP28 Active Optical Cable7Z57A03548AV1N
Lenovo 15m 100G QSFP28 Active Optical Cable7Z57A03549AV1P
Lenovo 20m 100G QSFP28 Active Optical Cable7Z57A03550AV1Q

The following table lists cables for the Mellanox EDR InfiniBand QSFP28 adapters.

Table 26. Cables for Mellanox EDR InfiniBand QSFP28 adapters

DescriptionPart numberFeature code
Passive copper cables for Mellanox EDR InfiniBand QSFP28 adapters*
0.5m Mellanox EDR IB Passive Copper QSFP28 Cable00MP516ASQT
0.75m Mellanox EDR IB Passive Copper QSFP28 Cable00MP520ASQU
1m Mellanox EDR IB Passive Copper QSFP28 Cable00MP524ASQV
1.25m Mellanox EDR IB Passive Copper QSFP28 Cable00MP528ASQW
1.5m Mellanox EDR IB Passive Copper QSFP28 Cable00MP532ASQX
2m Mellanox EDR IB Passive Copper QSFP28 Cable00MP536ASQY
3m Mellanox EDR IB Passive Copper QSFP28 Cable00MP560ASRM
Active optical cables for Mellanox EDR InfiniBand QSFP28 adapters*
3m Mellanox EDR IB Active Optical QSFP28 Cable00MP563ASRN
5m Mellanox EDR IB Active Optical QSFP28 Cable00MP540ASQZ
10m Mellanox EDR IB Active Optical QSFP28 Cable00MP544ASR0
15m Mellanox EDR IB Active Optical QSFP28 Cable00MP548ASR1
20m Mellanox EDR IB Active Optical QSFP28 Cable00MP552ASR2
30m Mellanox EDR IB Active Optical QSFP28 Cable00MP556ASR3
50m Mellanox EDR IB Active Optical QSFP28 Cable00MP566ASRP

* The Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter (00MM960) supports only a subset of the EDR InfiniBand cables listed in the table: 00MP516, 00MP524, 00MP536, and 00MP544.

The following table lists cables for the Intel Omni-Path QSFP28 adapters.

Table 27. Cables for Intel Omni-Path QSFP28 adapters

DescriptionPart numberFeature code
Passive copper cables for Intel Omni-Path QSFP28 adapters
0.5m Intel OPA 100 Series Passive Copper QSFP28 Cable00WE031AU0E
0.75m Intel OPA 100 Series Passive Copper QSFP28 Cable00WE035AU0F
1m Intel OPA 100 Series Passive Copper QSFP28 Cable00WE039AU0G
1.25m Intel OPA 100 Series Passive Copper QSFP28 Cable00WE043AU0H
1.5m Intel OPA 100 Series Passive Copper QSFP28 Cable00WE047AU0J
2m Intel OPA 100 Series Passive Copper QSFP28 Cable00WE051AU0K
3m Intel OPA 100 Series Passive Copper QSFP28 Cable00WE055AU0L
Active optical cables for Intel Omni-Path QSFP28 adapters
5m Intel OPA 100 Series Active Optical QSFP28 Cable00WE059AU0M
10m Intel OPA 100 Series Active Optical QSFP28 Cable00WE063AU0N
15m Intel OPA 100 Series Active Optical QSFP28 Cable00WE067AU0P
20m Intel OPA 100 Series Active Optical QSFP28 Cable00WE071AU0Q

SAS adapters for external storage

The following table lists SAS RAID controllers and HBAs for external storage attachments that are supported by the System x3650 M5 server.

Table 28. SAS RAID adapters and HBAs for external storage

DescriptionPart numberFeature codeMaximum supported*I/O slots supported
12 Gbps SAS RAID adapters
ServeRAID M5225-2GB SAS/SATA Controller00AE938A5ND2 / 31, 2, 3, 6‡
Feature on Demand (FoD) upgrades for the M5225 (one per server)**
ServeRAID M5200 Series RAID 6 Upgrade47C8706A3Z51**-
ServeRAID M5200 Series Performance Accelerator47C8710A3Z71**-
ServeRAID M5200 Series SSD Caching Enabler47C8712A3Z81**-
12 Gbps SAS HBAs
N2225 SAS/SATA HBA00AE912A5M02 / 51, 2, 3, 6, 7, 8‡
N2226 SAS/SATA HBA00AE916A5M12 / 51, 2, 3, 6, 7, 8‡

* The maximum quantity shown is with one processor / two processors.
‡ Slot 3 is supported only with the PCIe x16 Riser 1 (feature code A5FN).
** One FoD upgrade for the M5225 activates the feature on all M5200 series controllers (M5210, M5225) installed in the server.

Configuration note: Unless otherwise specified in the table footnote for the specific adapter, SAS RAID controllers and HBAs are supported in low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.

The following table summarizes features of supported RAID controllers and HBAs.

Table 29. SAS RAID controller and HBA features and specifications summary  (PN = Part number)

FeatureM5225-2GBN2226N2225
Part number00AE93800AE91600AE912
Form factorLow profileFull heightLow profile
Controller chipLSI SAS3108LSI SAS3008LSI SAS3008
Host interfacePCIe 3.0 x8PCIe 3.0 x8PCIe 3.0 x8
Port interface12 Gbps SAS12 Gbps SAS12 Gbps SAS
Number of external ports8168
External port connectors2x Mini-SAS HD
(SFF-8644)
4x Mini-SAS HD
(SFF-8644)
2x Mini-SAS HD
(SFF-8644)
Drive interfaceSAS, SATASAS, SATASAS, SATA
Drive typeHDD, SED, SSDHDD, SSDHDD, SSD
Maximum number of devices24010241024
RAID levels0/1/10/5/50;
Optional 6/60 (PN 47C8706)
NoneNone
JBOD modeNoYesYes
Cache2 GB (included)NoneNone
Cache protectionFlash (included)NoneNone
Performance Accelerator (FastPath)Optional (PN 47C8710)NoneNone
SSD Caching (CacheCade Pro 2.0)Optional (PN 47C8712)NoneNone

Fibre Channel host bus adapters

The following table lists Fibre Channel HBAs supported by the System x3650 M5 server.

Note: FC HBAs are supported in low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.

Table 30. Fibre Channel HBAs

DescriptionPart numberFeature codeMaximum supported*I/O slots supported
16 Gb Fibre Channel - PCIe
Emulex 16Gb Gen6 FC Single-port HBA01CV830ATZU3 / 72, 3, 4, 5, 6, 7, 8
Emulex 16Gb FC Single-port HBA81Y1655A2W53 / 72, 3, 4, 5, 6, 7, 8
Emulex 16Gb Gen6 FC Dual-port HBA01CV840ATZV3 / 72, 3, 4, 5, 6, 7, 8
Emulex 16Gb FC Dual-port HBA81Y1662A2W63 / 72, 3, 4, 5, 6, 7, 8
QLogic 16Gb Enhanced Gen5 FC Single-port HBA01CV750ATZB4 / 81, 2, 3, 4, 5, 6, 7, 8
QLogic 16Gb FC Single-port HBA00Y3337A3KW4 / 81, 2, 3, 4, 5, 6, 7, 8
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA01CV760ATZC4 / 81, 2, 3, 4, 5, 6, 7, 8
QLogic 16Gb FC Dual-port HBA00Y3341A3KX4 / 81, 2, 3, 4, 5, 6, 7, 8
8 Gb Fibre Channel - PCIe
Emulex 8Gb FC Dual-port HBA42D049435814 / 81, 2, 3, 4, 5, 6, 7, 8
Emulex 8Gb FC Single-port HBA42D048535804 / 81, 2, 3, 4, 5, 6, 7, 8
QLogic 8Gb FC Dual-port HBA42D051035794 / 81, 2, 3, 4, 5, 6, 7, 8
QLogic 8Gb FC Single-port HBA42D050135784 / 81, 2, 3, 4, 5, 6, 7, 8

* The maximum quantity shown is with one processor / two processors.

Flash storage adapters

The System x3650 M5 server supports the flash storage adapters listed in the following table.

Note: Flash storage adapters are supported in low profile PCIe x8 slots on the system board (low profile adapters only) and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.

Table 31. Flash storage adapters (LP = Low Profile PCIe adapter, FH = Full-High PCIe adapter)

DescriptionPart numberFeature codeMaximum supported*I/O slots supported
Enterprise Performance
Intel P3700 800GB NVMe AIC01GT711AVPY2 / 5**1, 4, 5, 6, 7
Intel P3700 1.6TB NVMe Enterprise Performance Flash Adapter (LP)00YA812AT7L2 / 51, 4, 5, 6, 7
Intel P3700 2.0TB NVMe Enterprise Performance Flash Adapter (LP)00YA815AT7M2 / 51, 4, 5, 6, 7
Enterprise Mainstream
io3 1.25TB Enterprise Mainstream Flash Adapter (LP)00YA800AT7N2 / 51, 4, 5, 6, 7
io3 1.6TB Enterprise Mainstream Flash Adapter (LP)00YA803AT7P2 / 51, 4, 5, 6, 7
1.92TB NVMe Enterprise Mainstream Flash Adapter (LP)00YK286AVP32 / 5**1, 4, 5, 6, 7
3.84TB NVMe Enterprise Mainstream Flash Adapter (LP)00YK287AVP42 / 5**1, 4, 5, 6, 7
io3 6.4TB Enterprise Mainstream Flash Adapter (FH)00YA809AT7R3 / 61, 2, 3, 6, 7, 8
Enterprise
1000GB Enterprise io3 Flash Adapter (LP)00AE995ARYP2 / 51, 4, 5, 6, 7
1300GB Enterprise io3 Flash Adapter (LP)00AE998ARYQ2 / 51, 4, 5, 6, 7
2600GB Enterprise io3 Flash Adapter (LP)00JY001ARYR2 / 51, 4, 5, 6, 7

* The maximum quantity shown is with one processor / two processors.
** Not supported with the Intel Xeon processor E5-2600 v3 product family.

Configuration notes:

  • With 3.5-inch drive bay models, the Flash Adapters are supported only in the environments with the air temperature of up to 30 °C (86 °F).
  • The io3 Flash Adapters cannot be factory installed; they are supported as field-installable options only. The server cannot be shipped with these adapters installed.

GPU adapters

The System x3650 M5 server supports graphics processing units (GPUs) listed in the following table.

Table 32. GPU adapters

DescriptionPart numberFeature codeMaximum supported**I/O slots supported
Full-high PCIe x16 adapters (x16-wired)
NVIDIA Grid K1 (Actively Cooled)00YL374AS3G1 / 21, 6
NVIDIA Quadro K6000None*A3YV1 / 21, 6
NVidia Quadro M5000 GPU, PCIe (active)00YL378ATZF1 / 21, 6
NVidia Quadro M6000 24GB GPU, PCIe (active)90Y2495AU3W1 / 21, 6
NVIDIA Tesla K40c00YL376A5FG1 / 21, 6
NVIDIA Tesla M10 GPU, PCIe (passive)7C57A02891AX8L1 / 2***1, 6
NVidia Tesla M60 GPU, PCIe (active)00YL377ASQL1 / 21, 6
NVIDIA Tesla P40 GPU, PCIe (passive)7C57A02888AVNZ1 / 2***1, 6
NVIDIA Tesla P100 PCIe 16GB (passive)7X67A00068AUV51 / 2***1, 6
Full-high PCIe x16 adapters (x8-wired)
NVIDIA Quadro K42000YL370ASPN2 / 41, 2, 6, 7
NVIDIA Quadro K62000YL371ASPP2 / 41, 2, 6, 7
NVIDIA Quadro K220000YL372ASQM2 / 41, 2, 6, 7

* These GPU adapters are available only through Special Bid or CTO.
** The maximum quantity shown is with one processor / two processors.
*** Not supported with the Intel Xeon processor E5-2600 v3 product family.

Configuration notes:

  • The NVIDIA PCIe x16 adapters (x16-wired) require PCIe x16 riser cards.
  • The NVIDIA PCIe x16 adapters (x8-wired) are supported with PCIe x8 or PCIe x16 riser cards, or a combination of PCIe x8 and PCIe x16 riser cards (with PCIe x16 riser cards, slots 2 [Riser 1] and 7 [Riser 2] are not available).
  • All GPUs installed in the server must be the same.
  • The maximum memory that can be installed is 1 TB.
  • Each M6000 GPU requires at least 48 GB of memory.
  • The GPU adapters are supported only in the environments with the air temperature of up to 35 °C (95 °F).
  • Passively cooled GPU adapters (part numbers 7C57A02891, 7C57A02888, and 7X67A00068) require the dual-rotor fans (included in a dual-rotor fan CTO base or in the optional x3650 M5 Dual Rotor Fan Thermal Kit [part number 00YD003]) and the optional x3650 M5 Passive GPU Thermal Kit (part number 01GV396).
  • Further restrictions may apply depending on the power supplies installed

Cooling

The System x3650 M5 server supports up to six system fans that provide dual fan zones cooling with N+1 fan
redundancy, and each system fan has one or two rotors depending on the model. System x3650 M5 servers with single-rotor fans can be upgraded to dual-rotor fan systems by replacing the existing single-rotor fans and cage with the dual-rotor fans and cage by using the optional Dual Rotor Fan Thermal Kit (part number 00YD003).

Single rotor fan-based server models of the System x3650 M5 with one processor include four system fans, and server models with two processors include six system fans. Dual-rotor fan server models of the System x3650 M5 include six system fans.

The following table shows additional cooling options.

Table 33. Cooling options

DescriptionPart numberFeature codeMaximum supported
System x3650 M5 PCIe Thermal Solution Kit00MU908ASQD1
System x3650 M5 Dual Rotor Fan Thermal Kit00YD003None1
System x3650 M5 Passive GPU Thermal Kit01GV396None1

Configuration notes:

  • The PCIe thermal solution kit (part number 00MU908) is required if any of the ML2 adapters are present in the configuration. The PCIe thermal kit contains an air baffle.
  • The Passive GPU Thermal Kit (part number 01GV396) is required when passively cooled GPU adapters (part numbers 7C57A02891, 7C57A02888, and 7X67A00068) are present in the configuration. The Passive GPU Thermal Kit contains an air duct, two low-profile heatsinks, four GPU power cables, and a full-length card holder.
  • The Dual Rotor Fan Thermal Kit (part number 00YD003) is required for single-rotor fan server models of the System x3650 M5 when passively cooled GPU adapters (part numbers 7C57A02891, 7C57A02888, and 7X67A00068) are present in the configuration. The Dual Rotor Fan Thermal Kit contains six dual-rotor fans and a fan cage.

Power supplies and cables

The System x3650 M5 server supports up to two redundant power supplies, and is capable of N+N redundancy depending on the configuration. Standard models come with one power supply. The following table lists the power supply options.

Table 34. Power supplies

DescriptionPart numberFeature codeMaximum supported
System x 550W High Efficiency Platinum AC Power Supply00FK930A5ET2
System x 750W High Efficiency Platinum AC Power Supply00FK932A5EU2
System x 750W High Efficiency Titanium AC Power Supply (200-240V)00FK934A5EV2
System x 900W High Efficiency Platinum AC Power Supply00FK936A5EW2
System x 900W High Efficiency -48 V DC Power Supply00MU910ASQF2
System x 1300W High Efficiency Titanium AC Power Supply (200-240V)00MU911ASQG2
System x 1500W High Efficiency Platinum AC Power Supply (200-240V)00MU909ASQE2

General power supply rules are as follows:

  • Minimum of 1 and maximum of 2 power supplies per system.
  • If 2 are installed, power supplies must be identical.

Important: The Standalone Solution Configuration Tool (SSCT) and Lenovo Data Center Advisor and Configurator Tool (DCACT) power supply selection rules allow a subset of possible configurations due to power restrictions. Configurations that cannot be built in SSCT or DCACT due to power restrictions may still be supported. To verify support and ensure that the right power supply is chosen for optimal performance, you should always validate your server configuration using the latest version of the System x Power Configurator:
https://support.lenovo.com/documents/LNVO-PWRCONF

The System x3650 M5 servers ship standard with or without a power cord (model dependent). The 900 W AC power supply option ships with one 2.8m, 13A/125V-10A/250V, IEC 320-C13 to C14 rack power cable (feature code 6400), and the other hot-swap AC power supply options ship standard with one 2.8m, 10A/100-250V, IEC 320-C13 to C14 rack power cable (feature code 6311).

Table 35. Power cables

DescriptionPart numberFeature code
Rack power cables
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable39Y79376201
2.0m, 10A/125-250V, C13 to IEC 320-C14 Rack Power CableNone*6316
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power CableNone*6311
2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power CableNone*6400
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable39Y79386204
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable39Y79326263
Country-specific line cords
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord39Y79306222
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord39Y79246211
Brazil 10A/125V C13 to 2P+Gnd 1.8m line cordNone*6599
Brazil 10A/250V C13 to 2P+Gnd 1.8m line cordNone*6364
Brazil 10A/125V C13 to NBR 6147 2.8m line cord39Y79296223
Brazil 10A/250V C13 to NBR 14136 2.8m line cord69Y19886532
China 10A/250V C13 to GB 2099.1 2.8m line cord39Y79286210
Denmark 10A/250V C13 to DK2-5a 2.8m line cord39Y79186213
Europe 10A/230V C13 to CEE7-VII 2.8m line cord39Y79176212
Europe 10A/250V, C13 to IEC 309 2P+Gnd 2.8m line cordNone*6377
Europe 10A/250V C13 to 2P+Gnd 4.3m line cordNone*6374
India 10A/250V C13 to IS 6538 2.8m line cord39Y79276269
Israel 10A/250V C13 to SI 32 2.8m line cord39Y79206218
Italy 10A/250V C13 to CEI 23-16 2.8m line cord39Y79216217
Japan 12A/125V C13 to JIS C-8303 2.8m line cord46M2593A1RE
Korea 12A/250V C13 to KETI 2.8m line cord39Y79256219
South Africa 10A/250V C13 to SABS 164 2.8m line cord39Y79226214
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord39Y79196216
Taiwan 10A/125V C13 to CNS 10917-3 1.8m line cordNone*6526
Taiwan 10A/250V C13 to CNS 10917-3 2.8m line cord00CG2656317
Taiwan 15A/125V C13 to CNS 10917-3 2.8m line cord00CG2676386
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord39Y79236215
United States 10A/125V C13 to NEMA 5-15P 1.8m line cordNone*6369
United States 10A/120V C13 to NEMA 5-15P 2.8m line cord90Y30166313
United States 10A/125V C13 to NEMA 5-15P 4.3m line cord39Y79316207
United States 10A/250V C13 to NEMA 6-15P 1.8m line cordNone*6351
United States 10A/250V C13 to NEMA 6-15P 2.8m line cord46M2592A1RF

* Available via Configure to Order (CTO).

Configuration note: If the 900 W AC power supplies (00FK936) in the System x3650 M5 server are connected to a low-voltage power source (100 - 125 V), the only supported power cables are those that are rated above 10A; cables that are rated at 10A are not supported.

Integrated virtualization

The System x3650 M5 server supports VMware ESXi installed on a USB memory key or one or two SD cards in the SD Media Adapter. The USB memory key is installed in a USB socket inside the server. The SD Media Adapter is installed in a dedicated slot inside the server.

When only one SD card is installed in the SD Media Adapter, you can create up to 16 volumes, each of which is presented to UEFI as a bootable device. When two SD Media cards are inserted, volumes can be mirrored (RAID 1) across both cards, up to a total of eight mirrored volumes. The RAID functionality is handled internally by the SD Media Adapter.

The following table lists the virtualization option.

Table 36. Virtualization option

DescriptionPart numberFeature codeMaximum supported
USB memory key
USB Memory Key for VMware ESXi 5.1 Update 200ML233ASN61
USB Memory Key for VMware ESXi 5.5 Update 200ML235ASN71
USB Memory Key for VMware ESXi 5.5 Update 3B00WH150ATZG1
USB Memory Key 4G for VMware ESXi 6.0 Update 1A00WH138ATRL1
USB Memory Key for VMware ESXi 6.0 Update 200WH151ATZH1
USB Memory Key for VMware ESXi 6.5None**AVNW1
Blank USB Memory Key 4G SLC for VMware ESXi Downloads00WH140ATRM1
Blank USB Memory Key for VMware ESXi Downloads41Y8298A2G01
SD Media Adapter and SD cards
SD Media Adapter (Option 00ML706 includes 2 blank 32GB SD cards)00ML706*A5TJ1
Blank SD Media for System x00ML700AS2V2
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (2 SD Media, RAIDed)None**AS4B1
RAID Adapter for SD Media w/ VMware ESXi 5.5 U2 (2 SD Media, RAIDed)None**AS4C1
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (1 SD Media)None**ASCG1
RAID Adapter for SD Media w/ VMware ESXi 5.5 U2 (1 SD Media)None**ASCH1
RAID Adapter for SD Media w/ VMware ESXi 5.5 U3B (1 SD Media)None**ATZK1
RAID Adapter for SD Media w/ VMware ESXi 5.5 U3B (2 SD Media, RAIDed)None**ATZJ1
RAID Adapter for SD Media w/VMware ESXi 6.0 U1A (1 SD Media)None**ATSA1
RAID Adapter for SD Media w/VMware ESXi 6.0 U1A (2 SD Media, RAIDed)None**ATS91
RAID Adapter for SD Media w/ VMware ESXi 6.0 U2 (1 SD Media)None**ATZM1
RAID Adapter for SD Media w/ VMware ESXi 6.0 U2 (2 SD Media, RAIDed)None**ATZL1
Lenovo SD Media RAID Adapter w/ VMware ESXi 6.0 U3 (1 SD)None**B17A1
Lenovo SD Media RAID Adapter w/ VMware ESXi 6.0 U3 (2 SD, Raided)None**B1791
Adapter for SD Media w/ VMware ESXi 6.5 (1 SD Media)None**AVNX1
Adapter for SD Media w/ VMware ESXi 6.5 (2 SD Media, RAIDed)None**AVNY1
Lenovo SD Media RAID Adapter w/ VMware ESXi 6.5 U1 (1 SD)None**B1781
Lenovo SD Media RAID Adapter w/ VMware ESXi 6.5 U1 (2 SD, Raided)None**B1771

* Option 00ML706 includes two 32GB SD cards; however, for CTO orders, feature code A5TJ does not include SD media and the 32 GB cards and VMware vSphere preload must be selected separately.
** CTO only.

Operating systems

The System x3650 M5 server supports the following operating systems:

  • Microsoft:
    • Microsoft Windows Server 2016
    • Microsoft Windows Server 2012 R2
    • Microsoft Windows Server 2012
    • Microsoft Windows Server 2008 R2 SP1
  • Red Hat:
    • Red Hat Enterprise Linux 7.3
    • Red Hat Enterprise Linux 7.2
    • Red Hat Enterprise Linux 6.8 Server x64 Edition
    • Red Hat Enterprise Linux 6.7 Server x64 Edition
  • SUSE:
    • SUSE Linux Enterprise Server 12 SP2
    • SUSE Linux Enterprise Server with Xen 12 SP2
    • SUSE Linux Enterprise Server 12 SP1
    • SUSE Linux Enterprise Server with Xen 12 SP1
    • SUSE Linux Enterprise Server 11 for AMD64/EM64T SP4
    • SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T SP4
  • VMware:
    • VMware vSphere 6.5 (ESXi)
    • VMware vSphere 6.0 (ESXi) Update 3
    • VMware vSphere 6.0 (ESXi) Update 2
    • VMware vSphere 5.5 (ESXi) Update 3

 

Systems management

The System x3650 M5 supports the following systems management tools:

  • Integrated Management Module 2.1
  • Light path diagnostics
  • Lenovo ToolsCenter
  • Lenovo XClarity Administrator
  • Lenovo XClarity Energy Manager

Integrated Management Module 2.1

The System x3650 M5 server contains Integrated Management Module II (IMM2.1), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2.1 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM2.1 also provides a virtual presence capability for remote server management capabilities.

The IMM2.1 provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Web browser

The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue-screen capture features. The remote presence feature provides the following functions:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
  • Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive

The blue-screen capture feature captures the video display contents before the IMM2.1 restarts the server when the IMM2.1 detects an operating system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition.

The following table lists the remote management option.

Table 37. Remote management option

DescriptionPart numberFeature codeMaximum supported
Integrated Management Module Advanced Upgrade90Y3901A1ML1

Light path diagnostics

All System x3650 M5 server models include basic light path diagnostics, which provides the system LEDs on the front of the server (see Components and connectors) and the LEDs near the monitored components (for example, the DIMM error LED on the system board).

Server models with 8x 3.5-inch or 8x or 16x 2.5-inch front drive bays support a next-gen light path diagnostics LCD display panel (standard on 8x 3.5-inch models; available as an option for 8x or 16x 2.5-inch models). With LCD display, you have quick access to system status, firmware, network, and health information.

Storage dense server models (models with USB ports and system LEDs that are located on the right EIA bracket) with 8x or 16x 2.5-inch front drive bays that are upgradeable to 24x 2.5-inch front drive bays and models with 12x 3.5-inch front drive bays do not support an LCD display panel.

The following table shows the LCD display panel ordering information.

Table 38. Light path diagnostics options

DescriptionPart numberFeature codeMaximum supported
x3650 M5 Front IO Cage Adv. (3x USB, LCD, Optional Optical Drive)00YD002*None*1

* The Front IO Cage Advanced part number (00YD002) includes the Front IO Cage Standard (feature code ATE6), System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8), and LCD display (feature code A4VH). If configured via CTO, the LCD display (feature code A4VH) is derived when the Front IO Cage Standard (feature code ATE6) and System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8) are selected.

Lenovo ToolsCenter

Lenovo offers the following ToolsCenter software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo ToolsCenter Suite

    The ToolsCenter Suite tool is a consolidation of server management tools that helps simplify the management of System x servers. It provides functions to collect full system health information (including health status), configure system setting, update system firmware and drivers, and FoD mass activation key management for multiple endpoints.

  • Lenovo ServerGuide

    The ServerGuide tool simplifies the process of configuring RAID and installing supported Microsoft Windows Server operating systems and device drivers on a System x server.

  • Lenovo UpdateXpress System Packs

    The UpdateXpress System Packs (UXSPs) are integration-tested bundles that enable you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages.

  • Lenovo Dynamic System Analysis

    The Dynamic System Analysis (DSA) pre-boot or standalone diagnostics software speeds up troubleshooting tasks to reduce service time.

Lenovo XClarity Administrator

Lenovo XClarity is a centralized systems management solution that helps administrators deliver infrastructure faster. This solution integrates easily with Lenovo x86 rack servers, Flex System, and RackSwitch switches, providing automated agent-less discovery, monitoring, firmware updates, configuration management, and bare metal deployment of operating systems and hypervisors across multiple systems.

Lenovo XClarity Administrator is an optional software component for the System x3650 M5 which can be downloaded and used at no charge to discover and monitor the x3650 M5 and manage firmware upgrades for them.

If software support is required for Lenovo XClarity Administrator, or Lenovo XClarity Administrator premium features (such as configuration management and operating system deployment) are required, or both, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.

The following table lists the geo-specific Lenovo XClarity software license options.

Table 39. Lenovo XClarity software options

DescriptionPart number
(NA, AP, Japan)*
Part number
(EMEA, LA)**
Quantity
Lenovo XClarity Pro, per Mngd Server w/1 Yr SW S&S00MT20100MT2071
Lenovo XClarity Pro, per Mngd Server w/3 Yr SW S&S00MT20200MT2081
Lenovo XClarity Pro, per Mngd Server w/5 Yr SW S&S00MT20300MT2091

* NA = North America; AP = Asia Pacific
** EMEA = Europe, Middle East, Africa; LA = Latin America

Lenovo XClarity Administrator offers the following standard features that are available at no charge:

  • Auto-discovery and monitoring of Lenovo x86 servers, RackSwitch switches, and Flex System chassis
  • Firmware updates and compliance enforcement
  • External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
  • Secure connections to managed endpoints
  • NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
  • Integration into existing higher level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
  • An intuitive, easy-to-use GUI
  • Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources

Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:

  • Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
  • Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning

In addition, Lenovo XClarity Administrator offers two software plug-in modules (Lenovo XClarity Integrators) at no charge (if software support is required, a Lenovo XClarity Pro software subscription license should be ordered):

  • Lenovo XClarity Integrator for Microsoft System Center
  • Lenovo XClarity Integrator for VMware vCenter

Lenovo XClarity Integrators allow administrators to manage physical infrastructure from leading external virtualization management software tools from Microsoft and VMware. Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to System x M5, M6, and X6 rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager provides a stand-alone, web-based agent-less power management console that provides real time data and enables you to observe, plan and manage power and cooling for Lenovo System x and ThinkServer x86 servers. Using built-in intelligence, it identifies server power consumption trends and ideal power settings and performs cooling analysis so that you can define and optimize power-saving policies.

Lenovo XClarity Energy Manager offers the following capabilities:

  • Reports vital server information, such as power, temperature and resource utilization
  • Monitors inlet temperature to locate hot spots, reducing the risk of data or device damage
  • Provides finely-grained controls to limit platform power in compliance with IT policy
  • Generates alerts when a user-defined threshold is reached

Lenovo XClarity Energy Manager is an optional software component for the System x3650 M5 that is licensed on a per managed node basis, that is, each managed server requires a license.

The following table lists the geo-specific Lenovo XClarity Energy Manager software license options.

Table 40. Lenovo XClarity Energy Manager software options

DescriptionPart number
(NA, AP, Japan)*
Part number
(EMEA, LA)**
Quantity
Lenovo XClarity Energy Manager, 1 Node w/ 1 Yr S&S01DA22501DA2281
Lenovo XClarity Energy Manager, 5 Nodes w/ 1 Yr S&S01DA22601DA2291
Lenovo XClarity Energy Manager, 50 Nodes w/ 1 Yr S&S01DA22701DA2301

* NA = North America; AP = Asia Pacific
** EMEA = Europe, Middle East, Africa; LA = Latin America

Rack installation

The following table lists the rack installation options that are available for the System x3650 M5 server.

Table 41. Rack installation options

DescriptionPart numberFeature codeMaximum supported
4-post rail kits
System x Enterprise Slides Kit00FK656A5FV1
System x Gen-II Universal Slides Kit00KA500A5FW1
System x M5 Custom Rail Kit00MW239ATLQ1
Cable management arm (CMA)
System x Enterprise 2U Cable Management Arm (CMA)00FK622A5FX1*
Lockable front bezel
System x3650 M5 Lockable Bezel00FK660A5G01
Front VGA port
System x3650 M5 EIA L - VGA00YD071ATE91

* The System x CMA requires the Enterprise Slides Kit (00FK656) or Universal Slides Kit (00KA500). The Custom Rail Kit (00MW239) is not supported with the CMA.

Note: The System x Enterprise Slides Kit, part number 00FK656, is included with the standard models that are listed in Table 2 and TopSeller models that are listed in Table 3.

The following table summarizes the rail kit features and specifications.

Table 42. Rail kit features and specifications summary

FeatureSystem x Enterprise
Slides Kit
System x Gen-II
Universal Slides Kit
System x M5
Custom Rail Kit
Part number00FK65600KA50000MW239
Rail typeFull-out slide (ball bearing)Full-out slide (ball bearing)Half-out slide (friction)
Toolless installationYesNoYes
CMA supportYesYesNo
In-rack server maintenanceYesYesNo
1U PDU supportYesYesYes
0U PDU supportLimited*Limited*Limited**
Rack typeIBM and Lenovo 4-post,
IEC standard-compliant
Any 4-post,
IEC standard-compliant
IBM and Lenovo 4-post,
IEC standard-compliant
Mounting holesSquare or roundSquare, round, or threadedSquare or round
Mounting flange thickness2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
4.65 mm (0.18 in.)
2 mm (0.08 in.) –
4 mm (0.16 in.)
Distance between front
and rear mounting flanges
617 mm (24.29 in.) –
812 mm (31.97 in.)
617 mm (24.29 in.) –
812 mm (31.97 in.)
595 mm (23.43 in.) –
746 mm (29.37 in.)
Rail length***833.5 mm (32.81 in.)836.8 mm (32.94 in.)755 mm (29.72 in.)

* The rack must be at least 1100 mm (43.31 in.) deep if no CMA is used, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** The rack must be at least 1000 mm (39.37 in.) deep.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.

Physical specifications

The System x3650 M5 server has the following dimensions and weight (approximate):

  • Height: 87 mm (3.4 in.)
  • Width: 434 mm (17.1 in.)
  • Depth: 755 mm (29.7 in.)
  • Weight:
    • Minimum configuration: 19 kg (41.8 lb)
    • Maximum configuration: 34 kg (74.8 lb)

Operating environment

The System x3650 M5 server is supported in the following environment:

  • Air temperature:
    • Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to 950 m (3,117 ft); decrease the maximum system temperature by 1 °C for every 175-m increase in altitude above 950 m.
    • Server off: 5 °C to 45 °C (41 °F to 113 °F)
    • Maximum altitude: 3,050 m (10,000 ft), 5 °C to 28 °C (41 °F to 82 °F)
    • Shipment: -40 °C to +60 °C (-40 °F to 140 °F) at up to 10,700 m (35,105 ft)
  • Humidity:
    • Server on: 8% to 85% (non-condensing), max dew point 24 °C, max rate of change 5 °C/hr
    • Server off: 8% to 85% (non-condensing), max dew point 27 °C
  • Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
    • Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
    • Under no circumstance can any combination of worst-case workload and configuration result in system shutdown or design exposure at 40 °C.
    • The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
  • Electrical:
    • Models with 1500 W Platinum power supplies:
      • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 8.35 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 1.967 kVA
    • Models with 1300 W Titanium power supplies:
      • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 7.137 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 1.700 kVA
    • Models with 900 W AC power supplies:
      • 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 10.3 A
      • 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 5.0 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 1.194 kVA
    • Models with 750 W Platinum AC power supplies:
      • 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.6 A
      • 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 1.015 kVA
    • Models with 750 W Titanium AC power supplies:
      • 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 0.965 kVA
    • Models with 550 W AC power supplies:
      • 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
      • 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 0.732 kVA
    • Models with -48Vdc 900 W power supplies:
      • -48 - -60 (nominal) V dc; 25.8 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 1.237 kVA
  • BTU output:
    • Minimum configuration: 525 Btu/hr (154 watts)
    • Maximum configuration: 6667 Btu/hr (1954 watts)
  • Acoustics:
    • 6.6 bels (operating)
    • 6.4 bels (idle)
  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg  - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Warranty

The System x3650 M5 has a three-year customer-replaceable unit (CRU) and onsite (for field-replaceable units [FRUs] only) limited warranty with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, refer to the Lenovo Enterprise Solutions Configurator (LESC):
http://lesc.lenovo.com

The following table explains warranty service definitions in more detail.

Table 43. Warranty service definitions

TermDescription
Onsite ServiceIf a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location. 
Parts DeliveredIf a problem with your product cannot be resolved via telephone and a CRU part is required, Lenovo will send a replacement CRU to arrive at your location. If a problem with your product cannot be resolved via telephone and a FRU part is required, a Service Technician will be dispatched to arrive at your location.  
Technician Installed PartsIf a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location.
Hours of coverage
  • 9x5: 9 hours per day, 5 days per week, during normal business hours, excluding local public and national holidays
  • 24x7: 24 hours per day, 7 days per week, 365 days per year.
Response time target2 hours, 4 hours, or Next Business Day: The time period from when the telephone based troubleshooting is completed and logged, to the delivery of the CRU or arrival of a Service Technician and part at the Customer’s location for repair.
Committed Repair6 hours: The time period between the service request registration in Lenovo’s call management system and the restoration of the product to conformance with its specification by a Service Technician. 

The following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • Three, four, or five years of 9x5 or 24x7 service coverage
    • Parts delivered or technician installed parts from next business day to 4 or 2 hours
    • Committed repair service
    • Warranty extension of up to 5 years
    • Post warranty extensions
  • Committed Service Repair

    Committed Service Repair (CSR) enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.

    • Priority handling to meet defined time frames to restore the failing machine to good working condition
    • 24x7x6 committed repair: Service performed 24 hours per day, 7 days per week, within 6 hours
  • YourDrive YourData

    Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Lenovo warranty upgrades and extensions.

  • Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.

  • Enterprise Software Support

    Lenovo Enterprise Server Software Support can help you troubleshoot your entire server software stack. Choose support for server operating systems from Microsoft, Red Hat, SUSE, and VMware; Microsoft server applications; or both operating systems and applications. Support staff can help answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

    In addition, you can access hardware “how to” support for System x servers. Staff can help resolve hardware problems not covered under warranty, refer you to the right documentation and publications, provide corrective service information for known defects, and transfer you to a hardware support call center if needed.

  • Hardware Installation Services

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities. Your new systems will be configured and ready for your software installation.

Regulatory compliance

The server conforms to the following regulations:

  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 5, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 22, Class A; AS/NZS 60950.1
  • China CCC GB4943.1, GB9254 Class A, GB17625.1
  • India IS 13252 (Part 1)
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • Korea KN22, Class A; KN24
  • Russia, Belorussia and Kazakhstan, TR CU 020/2011 (for EMC) and TR CU 004/2011 (for safety)
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
  • CISPR 22, Class A
  • TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000)
  • RoHS Directive
  • Energy Star 2.1

External drive enclosures

The following table lists the 6 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the System x3650 M5 for storage expansion.

Table 44. E1012 and E1024 external drive enclosure models

DescriptionPart number
Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD64111B1
Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD64111B2
Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD64111B3
Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD64111B4

The following table lists the 12 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the System x3650 M5 for storage expansion.

Table 45. External drive enclosures

DescriptionPart number
D1212 LFF Relationship models
D1212 LFF Chassis, Dual 3-port ESMs (US English documentation)4587A11*
D1212 LFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)4587A1C^
D1212 LFF Chassis, Dual 3-port ESMs (Japanese documentation)4587A1J**
D1212 LFF TopSeller models - Brazil and Latin America
D1212 LFF Chassis, Dual 3-port ESMs, 4x 2TB 3.5" HDDs, 4x 0.5m SAS cables4587EAU
D1212 LFF Chassis, Dual 3-port ESMs, 4x 4TB 3.5" HDDs, 4x 0.5m SAS cables4587EBU
D1212 LFF Chassis, Dual 3-port ESMs, 4x 6TB 3.5" HDDs, 4x 0.5m SAS cables4587ECU
D1212 LFF Chassis, Dual 3-port ESMs, 4x 8TB 3.5" HDDs, 4x 0.5m SAS cables4587EDU
D1212 LFF Chassis, Dual 3-port ESMs, 8x 2TB 3.5" HDDs, 4x 0.5m SAS cables4587EEU
D1212 LFF Chassis, Dual 3-port ESMs, 8x 4TB 3.5" HDDs, 4x 0.5m SAS cables4587EFU
D1212 LFF Chassis, Dual 3-port ESMs, 8x 6TB 3.5" HDDs, 4x 0.5m SAS cables4587EGU
D1212 LFF Chassis, Dual 3-port ESMs, 8x 8TB 3.5" HDDs, 4x 0.5m SAS cables4587EHU
D1212 LFF Chassis, Dual 3-port ESMs, 12x 2TB 3.5" HDDs, 4x 0.5m SAS cables4587EIU
D1212 LFF Chassis, Dual 3-port ESMs, 12x 4TB 3.5" HDDs, 4x 0.5m SAS cables4587EJU
D1212 LFF Chassis, Dual 3-port ESMs, 12x 6TB 3.5" HDDs, 4x 0.5m SAS cables4587EKU
D1212 LFF Chassis, Dual 3-port ESMs, 12x 8TB 3.5" HDDs, 4x 0.5m SAS cables4587ELU
D1212 LFF TopSeller models - North America (NA) and Europe, Middle East, and Africa (EMEA)
Lenovo Storage D1212 LFF Dual ESM Disk Expansion Enclosure (US English documentation)4587E11
D1224 SFF Relationship models
D1224 SFF Chassis, Dual 3-port ESMs (US English documentation)4587A31*
D1224 SFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)4587A3C^
D1224 SFF Chassis, Dual 3-port ESMs (Japanese documentation)4587A3J**
D1224 SFF TopSeller models - Brazil and Latin America
D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 0.5m SAS cables4587E6U
D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables4587E2U
D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables4587E4U
D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 1x 0.5m SAS cable4587E5U
D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables4587E1U
D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables4587E3U
D1224 SFF TopSeller models - North America (NA) and Europe, Middle East, and Africa (EMEA)
Lenovo Storage D1224 SFF Dual ESM Disk Expansion Enclosure (US English documentation)4587E31
D3284 Relationship models
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure641311F
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure641312F
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure641313F
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure641314F
D3284 TopSeller models
Lenovo Storage D3284 High Density Expansion Enclosure6413E5F
Lenovo Storage D3284 4TB x 42 HD Expansion Enclosure6413E1H
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure6413E1F
Lenovo Storage D3284 6TB x 42 HD Expansion Enclosure6413E2H
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure6413E2F
Lenovo Storage D3284 8TB x 42 HD Expansion Enclosure6413E3H
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure6413E3F
Lenovo Storage D3284 10TB x 42 HD Expansion Enclosure6413E4H
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure6413E4F

* Available worldwide (except China and Japan)
^ Available only in China
** Available only in Japan

External storage systems

The following table lists the external storage systems that are currently offered by Lenovo that can be used with the System x3650 M5 in IT solutions.

Table 46. External storage systems

DescriptionPart number
Lenovo ThinkSystem DS Series Storage (SAS connectivity)
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (US English documentation)4599A41*
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Simplified Chinese documentation)4599A4C^
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Japanese documentation)4599A4J**
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (US English documentation)4599A21*
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)4599A2C^
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Japanese documentation)4599A2J**
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (US English documentation)4617A41*
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Simplified Chinese documentation)4617A4C^
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Japanese documentation)4617A4J**
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (US English documentation)4617A21*
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)4617A2C^
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Japanese documentation)4617A2J**
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (US English documentation)4619A21*
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)4619A2C^
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Japanese documentation)4619A2J**
Lenovo ThinkSystem DS Series Storage (iSCSI or FC connectivity)
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (US English documentation)4599A31*
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)4599A3C^
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation)4599A3J**
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (US English documentation)4599A11*
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)4599A1C^
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation)4599A1J**
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (US English documentation)4617A31*
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)4617A3C^
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation)4617A3J**
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (US English documentation)4617A11*
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)4617A1C^
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation)4617A1J**
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (US English documentation)4619A11*
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)4619A1C^
Lenovo Storage V Series (SAS [except V7000/V7000F], iSCSI, or FC connectivity)
Lenovo Storage V3700 V2 LFF Control Enclosure6535C1D
Lenovo Storage V3700 V2 LFF Control Enclosure (TopSeller)6535EC1
Lenovo Storage V3700 V2 SFF Control Enclosure6535C2D
Lenovo Storage V3700 V2 SFF Control Enclosure (TopSeller)6535EC2
Lenovo Storage V3700 V2 XP LFF Control Enclosure6535C3D
Lenovo Storage V3700 V2 XP LFF Control Enclosure (TopSeller)6535EC3
Lenovo Storage V3700 V2 XP SFF Control Enclosure6535C4D
Lenovo Storage V3700 V2 XP SFF Control Enclosure (TopSeller)6535EC4
Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S6536C12
Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S6536C32
Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S6536C22
Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S6536C42
Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S6536B1F
Lenovo Storage V5030F SFF Control Enclosure 5Yr S&S6536B2F
Lenovo Storage V7000 SFF Control Enclosure 3Yr S&S PRC6538R11^
Lenovo Storage V7000 SFF Control Enclosure 5Yr S&S PRC6538R21^
Lenovo Storage V7000F SFF Control Enclosure 3Yr S&S PRC6538R1G^
Lenovo Storage V7000F SFF Control Enclosure 5Yr S&S PRC6538R2G^
IBM Storwize for Lenovo (SAS [except V7000], iSCSI, or FC connectivity)
IBM Storwize V3500 3.5-inch Dual Control Storage Controller Unit6096CU2^
IBM Storwize V3500 2.5-inch Dual Control Storage Controller Unit6096CU3^
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA6195C32†
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA6195C3L‡
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA6195C52†
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA6195C5L‡
Lenovo Storage DX8200 Series (NAS or iSCSI connectivity; optional FC connectivity)
Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 3yr SW S&S5135A3x#
Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 4yr SW S&S5135J3x#
Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 5yr SW S&S51351Wx#
Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 3yr SW S&S5135B3x#
Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 4yr SW S&S5135L3x#
Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 5yr SW S&S51352Wx#
Lenovo Storage DX8200D Storage Virtualization High, 64TB, 3yr SW S&S5135C3x#
Lenovo Storage DX8200D Storage Virtualization High, 64TB, 4yr SW S&S5135M3x#
Lenovo Storage DX8200D Storage Virtualization High, 64TB, 5yr SW S&S51353Wx#
Lenovo Storage DX8200D ServerSAN Entry, 8TB, 3yr SW S&S5135D3x#
Lenovo Storage DX8200D ServerSAN Entry, 8TB, 4yr SW S&S5135N3x#
Lenovo Storage DX8200D ServerSAN Entry, 8TB, 5yr SW S&S51354Wx#
Lenovo Storage DX8200D ServerSAN Mid, 16TB, 3yr SW S&S5135F3x#
Lenovo Storage DX8200D ServerSAN Mid, 16TB, 4yr SW S&S5135P3x#
Lenovo Storage DX8200D ServerSAN Mid, 16TB, 5yr SW S&S51355Wx#
Lenovo Storage DX8200D ServerSAN High, 32TB, 3yr SW S&S5135G3x#
Lenovo Storage DX8200D ServerSAN High, 32TB, 4yr SW S&S5135Q3x#
Lenovo Storage DX8200D ServerSAN High, 32TB, 5yr SW S&S51356Wx#
Lenovo Storage DX8200N with 1x N2226 HBA (Requires a supported external drive enclosure)5128C1x#
Lenovo Storage DX8200N with 2x N2226 HBAs (Requires a supported external drive enclosure)5128C2x#
Lenovo Storage DX8200C Series (S3 cloud storage)
Lenovo Storage DX8200C 56TB (14x 4TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S5120D1x#
Lenovo Storage DX8200C 84TB (14x 6TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S5120D2x#
Lenovo Storage DX8200C 112TB (14x 8TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S5120D3x#
Lenovo Storage DX8200C 140TB (14x 10TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S5120D4x#

* Available worldwide (except China and Japan).
^ Available only in China.
** Available only in Japan.
† Available worldwide except Latin America.
‡ Available only in Latin America.
# x represents a geo-specific letter (for example: U = North America, G = EMEA). Ask a Lenovo representative for specifics.

External backup units

The following table lists the external backup options that are offered by Lenovo that can be used with the System x3650 M5 in backup solutions.

Table 47. External backup options

DescriptionPart number
External RDX USB drives
RDX External USB 3.0 Dock with 320GB Cartridge362532Y
RDX External USB 3.0 Dock with 500GB Cartridge362550Y
RDX External USB 3.0 Dock with 1TB Cartridge36251TY
External SAS tape backup drives
IBM TS2250 Tape Drive Model H5S6160S5E
IBM TS2260 Tape Drive Model H6S6160S6E
IBM TS2270 Tape Drive Model H7S6160S7E
External SAS tape backup autoloaders
IBM TS2900 Tape Autoloader w/LTO5 HH SAS6171S5R
IBM TS2900 Tape Autoloader w/LTO6 HH SAS6171S6R
IBM TS2900 Tape Autoloader w/LTO7 HH SAS6171S7R
External tape backup libraries
IBM TS3100 Tape Library Model L2U61732UL
IBM TS3200 Tape Library Model L4U61734UL
Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries
6173 LTO Ultrium 5 Fibre Channel Drive00NA107
6173 LTO Ultrium 5 Half High Fibre Drive Sled00NA113
6173 LTO Ultrium 6 Fibre Channel Drive00NA115
6173 LTO Ultrium 6 Half High Fibre Drive Sled00NA119
6173 LTO Ultrium 7 Fibre Channel Drive00WF765
6173 LTO Ultrium 7 Half High Fibre Drive Sled00WF769
SAS backup drives for TS3100 and TS3200 Tape Libraries
6173 LTO Ultrium 5 SAS Drive Sled00NA109
6173 LTO Ultrium 5 Half High SAS Drive Sled00NA111
6173 LTO Ultrium 6 Half High SAS Drive Sled00NA117
6173 LTO Ultrium 7 Half High SAS Drive Sled00WF767

 

Ethernet LAN switches

The following table lists the Ethernet LAN switches that are offered by Lenovo that can be used with the System x3650 M5 server in IT solutions.

Table 48. Ethernet LAN switches

DescriptionPart number
1 Gb Ethernet switches
Juniper EX2300-C PoE Switch7165H1X
Juniper EX2300-24p PoE Switch7165H2X
Lenovo RackSwitch G7028 (Rear to Front)7159BAX
Lenovo RackSwitch G7052 (Rear to Front)7159CAX
Lenovo RackSwitch G8052 (Rear to Front)7159G52
10 Gb Ethernet switches
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)7159A1X
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)7159B1X
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)7159C1X
Lenovo RackSwitch G8124E (Rear to Front)7159BR6
Lenovo RackSwitch G8264 (Rear to Front)7159G64
Lenovo RackSwitch G8264CS (Rear to Front)7159DRX
Lenovo RackSwitch G8272 (Rear to Front)7159CRW
Lenovo RackSwitch G8296 (Rear to Front)7159GR6
25 Gb Ethernet switches
Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)7159E1X
40 Gb Ethernet switches
Lenovo RackSwitch G8332 (Rear to Front)7159BRX
100 Gb Ethernet switches
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)7159D1X

 

Fibre Channel SAN switches

The following table lists currently available Fibre Channel SAN switches that are offered by Lenovo that can be used with the System x3650 M5 in IT solutions.

Table 49. Fibre Channel SAN switches

DescriptionPart number
8 Gb FC
Lenovo B300, 8 ports activated, 8x 8Gb SWL SFPs, 1 PS, Rail Kit3873AR3
Lenovo B6505, 12 ports activated, 12x 8Gb SWL SFPs, 1 PS, Rail Kit3873AR4
Lenovo B6510, 24 ports activated, 24x 8Gb SWL SFPs, 2 PS, Rail Kit3873BR2
16 Gb FC
Lenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit6559D2Y
Lenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFP, Enterprise SW, 1 PS, Rail Kit6559D1Y
Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit3873AR5
Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit3873BR3
32 Gb FC
Lenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit6559D3Y
Lenovo ThinkSystem DB620S, 24 Ports Activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit6415G11
Lenovo ThinkSystem DB620S, 48 Ports Activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit6415G2A
Lenovo ThinkSystem DB400D 32Gb FC Director, up to 192 ports, 8U, Enterprise SW6684B2A
Lenovo ThinkSystem DB800D 32Gb FC Director, up to 384 ports, 14U, Enterprise SW6682B1A

 

Rack cabinets

The following table lists the rack cabinets that are offered by Lenovo that can be used in System x3550 M5 solutions.

Table 50. Rack cabinets

DescriptionPart number
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments)93072RX
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments)93072PX
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments)93074RX
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments)93634PX
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments)93634EX
42U 1200mm Deep Dynamic Rack (6 sidewall compartments)93604PX
42U 1200mm Deep Static Rack (6 sidewall compartments)93614PX
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments)93084PX
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments)93084EX

 

KVM switches and consoles

The following table lists the KVM switches and consoles that are offered by Lenovo that can be used in System x3650 M5 solutions.

Table 51. KVM switch and console options

DescriptionPart number
Consoles
1U 18.5" Standard Console (without keyboard)17238BX
Console keyboards
Lenovo UltraNav Keyboard USB - US Eng00MW310
Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v246W6713
Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v246W6714
Keyboard w/ Int. Pointing Device USB - Chinese/US 467 RoHS v246W6715
Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v246W6716
Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v246W6717
Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v246W6718
Keyboard w/ Int. Pointing Device USB - French 189 RoHS v246W6719
Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v246W6720
Keyboard w/ Int. Pointing Device USB - German 129 RoHS v246W6721
Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v246W6722
Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v246W6723
Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v246W6724
Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v246W6725
Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v246W6726
Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v246W6727
Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v246W6728
Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v246W6729
Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v246W6730
Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v246W6731
Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v246W6732
Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v246W6733
Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v246W6734
Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v246W6735
Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v246W6736
Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v246W6737
Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v246W6738
Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v246W6739
Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v246W6740
Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v246W6741
Console switches
Global 4x2x32 Console Manager (GCM32)1754D2X
Global 2x2x16 Console Manager (GCM16)1754D1X
Local 2x16 Console Manager (LCM16)1754A2X
Local 1x8 Console Manager (LCM8)1754A1X
Console cables
Single Cable USB Conversion Option (UCO)43V6147
USB Conversion Option (4 Pack UCO)39M2895
Virtual Media Conversion Option Gen2 (VCO2)46M5383
Serial Conversion Option (SCO)46M5382

 

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in System x3650 M5 solutions.

Table 52. Uninterruptible power supply units

DescriptionPart number
RT1.5kVA 2U Rack or Tower UPS (100-125VAC)55941AX
RT1.5kVA 2U Rack or Tower UPS (200-240VAC)55941KX
RT2.2kVA 2U Rack or Tower UPS (100-125VAC)55942AX
RT2.2kVA 2U Rack or Tower UPS (200-240VAC)55942KX
RT3kVA 2U Rack or Tower UPS (100-125VAC)55943AX
RT3kVA 2U Rack or Tower UPS (200-240VAC)55943KX
RT5kVA 3U Rack or Tower UPS (200-240VAC)55945KX
RT6kVA 3U Rack or Tower UPS (200-240VAC)55946KX
RT8kVA 6U Rack or Tower UPS (200-240VAC)55948KX
RT11kVA 6U Rack or Tower UPS (200-240VAC)55949KX
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)55948PX
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)55949PX

 

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in System x3650 M5 solutions.

Table 53. Power distribution units

DescriptionPart number
0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord00YJ776
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord00YJ777
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord00YJ778
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord00YJ779
Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord00YJ781
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord00YJ780
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord00YJ782
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord00YJ783
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)46M4002
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord46M4003
1U 12 C13 Switched and Monitored DPI PDU (without line cord)46M4004
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord46M4005
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord)71762NX
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord71763NU
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
DPI C13 Enterprise PDU+ (without line cord)39M2816
DPI Single Phase C13 Enterprise PDU (without line cord)39Y8941
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord)39Y8948
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord39Y8923
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord39Y8938
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord39Y8939
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord39Y8934
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord39Y8940
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord39Y8935
Universal PDUs (7x IEC 320 C13 outlets)
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord)00YE443
NEMA PDUs (6x NEMA 5-15R outlets)
DPI 100-127V PDU with fixed NEMA L5-15P line cord39Y8905
Line cords for PDUs that ship without a line cord
DPI 30a Line Cord (NEMA L6-30P)40K9614
DPI 32a Line Cord (IEC 309 P+N+G)40K9612
DPI 32a Line Cord (IEC 309 3P+N+G)40K9611
DPI 60a Cord (IEC 309 2P+G)40K9615
DPI 63a Cord (IEC 309 P+N+G)40K9613
DPI Australian/NZ 3112 Line Cord (32A)40K9617
DPI Korean 8305 Line Cord (30A)40K9618

 

  • Views: 10764
  • Brand: IBM
  • Product Code: Lenovo IBM System x3650 M5
  • Rack: 2U
    Hotline: 0904092014
    Warranty: 3 Years
  • Availability: In Stock
  • Contact us