Dell EqualLogic FS7600 and FS7610 with FluidFS v4
Click image for gallery

Optimized platform for high-speed storage and low TCO
The next-generation Dell Fluid File System version 4 (FluidFS v4), with the enterprise-class FS7600 and FS7610, scales performance and capacity on the fly and delivers better file OPS performance at a lower price than the leading solution. Get more performance and lower TCO along with:
- Linear performance expansion up to 494,000 max SPECsfs file OPS and 11.9 GB/sec max throughput1
- Improved performance with mirrored cache and automated load balancing, even as you add more data
- Lower costs with one of the most competitive price per performance scale-out NAS solutions available
-1.jpg)
-1.jpg)
Specifications | |
Chassis | Height 2U / 86.4 mm (3.4 inches)Width 481.50 mm (18.96 inch) with rack flange. 446.3 mm (17.6 inches)—Does not include rack flange.Depth 741.0 mm (29.2 inches)—Without bezel and handle 813.0 mm (32.0 inches)—With bezel and handleWeight (Maximum configuration) 30.5 kg (67 lbs)Rack Support ReadyRails II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded-hole racks |
Environmental Operating Conditions | TemperatureContinuous operation 5 °C to 40 °C (41 °F to 104 °F) with a maximum temperature gradation of 20 °C per hour.Storage: -40 °C to -60°C (–40 °F to 140 °F) with a maximum temperature gradation of 20 °C per hour.Relative humidityOperating: 20% to 80% (non-condensing) with maximum humidity gradation of 10% per hour at maximum wet bulb temperature of 29 °C (89 °F)Non-operating: 5% to 95% with a maximum humidity gradation of 10% per hour at a maximum wet bulb temperature of 38 °C (100 °F)Maximum vibrationOperating: 0.26 Grms (5 Hz – 350 Hz @ 0.0002G2/Hz) in operational orientation for 5 minutes (maximum)Non-operating: 1.88 Grms with the following PSD profile (all 6 sides tested for 15 minutes each side)Frequency (Hz) G2/Hz 10 0.13 20 0.13 70 0.004 130 0.004 165 0.0018 500 0.0018Maximum shockOperating 31G half-sine shock +/-5% with pulse duration of 2.6ms +/- 10% in the operational orientation (Maximum)Non-operating Square wave shock of 27 G, at 235 inches/second (596.90 cm/second) velocity change (all six sides tested)Operating altitude-16 to 3048 m (-50 to 10,000 feet) For altitudes above 2950 feet, the maximum operating temperature is derated 1° F/550 feet.Non-operating –15.2 m to 10,668 m (–50 ft to 35,000 ft)Airborne Contaminant Level Class G1 as defined by ISA-S71.04-1985 |
Power | Wattage 717W output per applianceVoltage 90 V AC to 264V AC, autoranging, 47 Hz/63 Hz. Note: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.Heat dissipation 2446 BTU/hr. Note: The heat dissipation is calculated using the power supply wattage rating. The heat dissipation values are for the entire system which includes (chassis and two controllers).Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less |